Содержание P2

Страница 1: ......

Страница 2: ...s ClearEnergy P2 is an all in one plug n play energy charging storage and powering solution It can power refrigerators lights TV s internet modems microwaves fans and more if your home loses power from the grid or if you need power on the go ClearEnergy Docking station integrates the P2 into your homes breaker panel and circuits to automatically charge via grid or solar and power up to 3 essential...

Страница 3: ...ter before starting installation 1 Identify installation location of the Docking Station Most installations are done in utility rooms in proximity to the home s breaker panel 2 Use Template to mark the lag locations that correspond with the lag holes on the back of the docking station and the hole for the provided power whip called the ClearEnergy installation cable 3 Make sure lags will screw int...

Страница 4: ...diagram in order to easily match with the labeled wires on the ClearEnergy installation cable 5 Connect to corresponding wires on the ClearEnergy installation cable located in the 4 Square Box 6 Connect corresponding wires hot neutral and ground to the breakers following the provided wiring guide and wire numbers 7 Energize the breaker panel and test 1 Run PV wire from the solar panels through app...

Страница 5: ... 18 AWG signal wires from the ClearEnergy RelayBox to the 4 Square box dedicated to the ClearEnergy DockingStation 7 Connect solar wires in the RelayBox and junction box 8 Connect the signal wires in the RelayBox and in the Junction Box 9 Re install plates and re mount solar panels 10 Test Tool Appearance Description Multimeter Used to check cabinet insulation and cable connection and measure elec...

Страница 6: ...tripper Used to remove the insulation layer and jacket from a communication cable with a small cross sectional area PVC insulation tape Used to insulate wires and conductors Cotton cloth Used to clean panels and shells Heat shrink tubing M6 Used to insulate wires and conductors Heat gun Used to heat a heat shrink tubing ...

Страница 7: ...electrostatic discharge ESD from damaging a board or other electrostatic sensitive devices ESSDs when you insert or remove a board or hold an ESSD Insulated gloves Used to insulate hands Hydraulic pliers Used to crimp the OT terminals and JG terminals with a large cross sectional area of 10 mm2 16 mm2 25 mm2 or 35 mm2 Cable tie Used to bind cables ...

Страница 8: ...to Docking Station White 14 AWG 3 Circuit 1 From Breaker Red 12 AWG 4 Circuit 2 From Breaker Red 12 AWG 5 Circuit 3 From Breaker Red 12 AWG 6 Appliance Circuit 3 Black 12 AWG 7 Neutral 1 to Neutral Bar White 14 AWG 8 Appliance Circuit 2 Black 12 AWG 9 Neutral 2 to Neutral Bar White 14 AWG 10 Appliance Circuit 1 Black 12 AWG 11 Neutral 3 to Neutral Bar White 14 AWG 12 Empty ...