Clear-Com Encore TWC-703 Скачать руководство пользователя страница 6

Encore TWC-703 Adapter

NOTE:

This equipment has been tested and found to comply with the limits for a Class A digital

device, pursuant to Part 15 of the FCC rules. These limits are designed to provide reasonable

protection against harmful interference when the equipment is operated in a commercial

environment. This equipment generates, uses and can radiate radio frequency energy and, if

not installed and used in accordance with the instruction manual, may cause harmful

interference to radio communication. Operation of this equipment in a residential area is likely to

cause harmful interference, in which case the user will be required to correct the interference at

his own expense.

Changes or modifications not expressly approved by Clear-Com could void the user’s authority

to operate this equipment.

1.1.2

Canada ICES-003

Industry Canada ICES-003 Compliance Label: CAN ICES-3 (A)/NMB-3(A) This Class A digital

apparatus complies with Canadian ICES-003.

Cet appareil numèrique de la classe A est conforme á la norme NMB-003 du Canada.

1.1.3

European Union ( CE )

Hereby, Clear-Com LLC declares that the product described herein are in compliance with the

following regulations:

Directives:

EMC Directive 2014/30/EU

RoHS Directive 2011/65/EU, 2015/863

Standards:

EN 55032 / CISPR 32

EN 55035 / CISPR 35

EN 61000-3-2

EN 61000-3-3

Warning:

This is a Class A product. In a residential environment, this product may cause radio

interference in which case the user may be required to take adequate measures.

Note:

During the conducted and radiated immunity tests, an audible tone can be heard in certain

frequencies. The TWC-703 continued to operate and the tones did not interfere or diminish its

functions. The tones can be reduced, and in some cases, be eliminated by the following:

1. If using the power adapter for the TWC-703, use a ferrite clamp, Laird 28A2024-0A2 or

similar. Make one loop of the power cable around the clamp as close as possible to the

Page 6

Содержание Encore TWC-703

Страница 1: ...User Guide Encore TWC 703 Adapter User Guide Date June 03 2021 Part Number PUB 00039 Rev A...

Страница 2: ...lation reverse engineering No part of this document may be reproduced in any form by any means without prior written authorization of Clear Com an HME Company Clear Com Offices are located in Californ...

Страница 3: ...12 3 1 Normal Mode 13 3 2 Power Injection Mode 14 3 3 Stand Alone Mode 14 3 4 Internal Configuration 15 4 Technical Specifications 16 4 1 Connectors Indicators and Switches 16 4 2 Power requirements 1...

Страница 4: ...hen moving the cart apparatus combination to avoid injury from tip over 11 Unplug this apparatus during lightning storms or when unused for long periods of time 12 Refer all servicing to qualified ser...

Страница 5: ...t with regulatory requirements detailed in this document when installed correctly in Clear Com product per Clear Com specifications Caution Product modification not expressly approved by the party res...

Страница 6: ...CAN ICES 3 A NMB 3 A This Class A digital apparatus complies with Canadian ICES 003 Cet appareil num rique de la classe A est conforme la norme NMB 003 du Canada 1 1 3 European Union CE Hereby Clear...

Страница 7: ...wn below is on the product or on its packaging which indicates that this product was put on the market after August 13 2005 and must not be disposed of with other waste Instead it is the user s respon...

Страница 8: ...Encore TWC 703 Adapter Warning This is a Class A product In a residential environment this product may cause radio interference in which case the user may be required to take adequate measures Page 8...

Страница 9: ...between channels On standard cabling one conductor pin 2 carries power to the remote stations The second conductor pin 3 carries full duplex two way intercom audio and call signaling The shield or dra...

Страница 10: ...ctor 4 Short circuit dual LED Green normal operation Red Overload Note When an external power supply is used the red LED flashes red during overload Otherwise the red LED is always on during overload...

Страница 11: ...Encore TWC 703 Adapter 2 2 2 Clear Com Partyline Pinout 2 2 3 TW Partyline Pinout Page 11...

Страница 12: ...as a stand alone device that can power up to 12 RS 703 two wire beltpacks or their equivalent This stand alone TWC 703 creates a small dual channel TW intercom system This configuration requires an ex...

Страница 13: ...om Disabling the call translation switches is only necessary if one channel is sent through multiple TWC 703 Adapters Note RS703 Beltpacks must be configured for RTS TW using DIP switches Note To oper...

Страница 14: ...using the external PSU 453G023 Note The PSU is not included with the TWC 703 Adapter and must be ordered separately A typical system connection example is given below 3 3 1 To connect and operate the...

Страница 15: ...nfigure auto termination of channel B Default is ON l J10 used to enable or disable RTS Compatibility Mode Default is OFF Note The TWC 703 Adapter applies termination per channel if there is no power...

Страница 16: ...3F TW 1 x XLR3M Front panel indicator Power On green Overload red DC power input connector Call translation switch for channel A Call translation switch for channel B Power Overload indicator 4 2 Powe...

Страница 17: ...tions While Clear Com makes every attempt to maintain the accuracy of the information contained in its product manuals that information is subject to change without notice Performance specifications i...

Страница 18: ...online and e mail technical support will be provided by the Customer Service Center free of charge during the Warranty Period b Technical support will be provided free of charge for all software produ...

Страница 19: ...support enquires rather than using the Customer Service Centers directly f Support for Direct Sales i Customers may utilize the Customer Service Centers once a system has been installed and commission...

Страница 20: ...e replacement or will be invoiced for the list price of a new product iii To obtain an RMA number or request an AWR North and South America Asia Pacific and US Military Hours 0800 1700 Pacific Time Da...

Страница 21: ...d Return for Repair i Customers are required to ship equipment at their own cost including transportation packing transit insurance taxes and duties to Clear Com s designated location for repair Clea...

Отзывы: