SAFETY INSTRUCTIONS

WARNING!

When using an electrical appliance, basic precautions should always be followed.

To reduce the risk of fire, electric shock or injury following these tips:

1. 

Do not leave appliance plugged in. Unplug from outlet when not in use.

2.  

Electric shock could occur if used outdoors or on wet surfaces.

3.  

Keep away from children. Extractor is not to be used as a toy.

4.  

Use only as described in this manual. Use only manufacturer’s recommended parts.

5.  

Do not use extractor with damaged power cords.

6.  

Do not abuse the power cord. Do not pull or carry extractor with the power cord. Do not use the power cord  

 

as a handle. Do not close doors on the power cord. Do not pull power cord around sharp edges or corners.  

 

Do not run the extractor over the power cord. Do not keep power cords around heated surfaces.

7.  

Do not unplug by pulling on electric power cord. To unplug, grasp the plug, not the electric power cord.

8.  

Do not handle plug or appliance with wet hands.

9.  

Do not put any object into openings. Do not use with any opening blocked; keep free of dust, lint, hair and  

 

anything that may reduce air flow.

10.  

Keep hair, loose clothing, fingers and all parts of body away from openings and moving parts.

11.  

Do not pick up anything that is burning or smoking, such as cigarettes, matches or hot ashes.

12.  

Do not use extractors without filters.

13.  

Turn off all controls before unplugging from electric outlet.

14.  

Use extra care when cleaning on stairs.

15.  

Always wear safety equipment and appropriate clothing when operating the extractor. 

16.  

Do not use extractor to pick up flammable or combustible liquids such as gasoline or use in areas where such  

 

items may be present.

17.  

Connect to a properly grounded electric power outlet only.

18.  

Do not attempt to service the extractor while appliance is plugged in.

 

5

Содержание CF-100 Series

Страница 1: ...LLUSTRATIONS ARE FOR REFERENCE ONLY ACTUAL PRODUCTS MAY NOT BE EXACTLY AS SHOWN Owner s Manual CF 100 SERIES MODEL CF 100 CF 100 HEAT CF 25XG CF 25XG HEAT 5109 N NATIONAL DR KNOXVILLE TN 37914 TEL 888...

Страница 2: ......

Страница 3: ...NTENANCE 10 HOW TO 12 How to use attachment tools How to bleed the system System without electric instant water heater System with electric instant water heater OPTIONS 14 Auto Dump Pump Auto Fill Che...

Страница 4: ...purchase by sending CleanFreak the warranty registration form within 10 days of purchase Page 5 This warranty is in lieu of all other warranties expressed or implied and no person is authorized to gi...

Страница 5: ...ated surfaces 7 Do not unplug by pulling on electric power cord To unplug grasp the plug not the electric power cord 8 Do not handle plug or appliance with wet hands 9 Do not put any object into openi...

Страница 6: ...pump optional drain valve pressure gauge unloader valve aka pressure regulator two circuit TEST SWITCH only with two power cords unit standard equipment for unit with 500 psi pump reset switch for le...

Страница 7: ...image ground blade DO NOT break off three prong receptacle image 9 1 CONNECT HOSE Vacuum hose connection to attachment tool Solution hose connection to attachment tool quick connector Solution hose l...

Страница 8: ...tes that you are not on two separate circuits and are increasing your chance of a circuit blowout 2 Always thoroughly pre vacuum the surface to be cleaned Using an upright vacuum cleaner or the extrac...

Страница 9: ...o clean water tank Vacuum out all the excess water see below image 11 2 3 Drain and thoroughly clean the recovery tank At this point the tank can be rinsed while dumping 4 The vacuum filter wet filter...

Страница 10: ...and debris into the solution lines that will block filters orifices and generally degrade the systems 4 Keep equipment out of extreme temperatures i e Freezing temperatures will make water expand and...

Страница 11: ...FILTER A clean vacuum filter must be installed in the recovery tank at all times to protect the motor See below image 13 1 IMAGES AND ILLUSTRATIONS ARE FOR REFERENCE ONLY ACTUAL PRODUCTS MAY NOT BE E...

Страница 12: ...pulling back on the wand image 14 3 14 2 Pull the tool with the valve lever pressed to insure the best results 2 Release the solution control valve lever image 14 4 14 1 and pass the tool over the da...

Страница 13: ...clean water 2 Connect desired tool and extractor with vacuum hose and solution hose 3 Turn pump switch to ON 4 Open trigger valve from your attachment tool See image 15 1 and spray until all air is o...

Страница 14: ...lean water tank is empty and or cleaning job is done 8 Turn off all the switches and disconnect electric power cord from power plug then empty the left over recovery tank into a bucket or another prop...

Страница 15: ...tank fill up No need to turn off water faucet until cleaning job is completed NOTE 1 If IN LINE hose is dirty or not used recently clean before use 2 Water needs to be flowing into the extractor const...

Страница 16: ...l feed system page chemical feed mixing quick connect from chemical feed line to extactor quick connect See below image 18 3 image shown Chemical bottle hand on the extractor CHEMICAL FEED MIXING SYST...

Страница 17: ...in powder form mix it with water thoroughly make sure it is fully dissolved Any undissolved powder can clog up the flowmeter spray jets and other parts on the extractor damaging them in the process A...

Страница 18: ...r to the chart See image 20 3 Can be found metering system in between solution tank and the pump plumbing system OPTIONS metering preset chemical feed system tips TO USE Have a bottle or bucket of cle...

Страница 19: ...heater switch ON and wait approximatley 3 4 minutes to heat up Now it is ready to use The in line heater has a pre set thermostat for 210 degrees fahrenheit Keep solution tank clean and do not use any...

Страница 20: ...urn pump switch to ON 4 Open trigger valve from attachment tool See image 22 1 And spray until all air out from the solution system See image 22 1 if no trapped air in the system water should spray th...

Страница 21: ...ent or electric cord not grounded See authorized repair person Pump motor stopped 1 Pressure build up cause by jet clogged 1 Released pressure by opening up press the lever on the Wand 2 Thermal overl...

Страница 22: ...um hose 8 See authorized repair person connection inside the extractor 9 Foriegn object accumulated in 9 See authorized repair person vacuum fans Vacuum motors run intermittently See authorized repair...

Страница 23: ...heater 1 Bleed See How to bleed page 2 Bad thermostat 2 Replace 3 Heating element burned out 3 Replace 4 Safety valve open 4 Check safety valve and close it WARNING This product contains chemicals kno...

Страница 24: ...All rights reserved 5109 N NATIONAL DR KNOXVILLE TN 37914 TEL 888 722 5508 WWW CLEANFREAK COM R...