TROUBLE-SHOOTING
21
ELECTRICAL SYSTEM
PUMP SYSTEM
TROUBLE-SHOOTING
No electrical power
1. Check the outlet & the plug
1. Plug in properly
(Component or extractor
2. Damage cord
2. See authorized repair person
not turning on )
3. Circuit breaker off or fuse blown
3. Flip circuit breaker on or replace
fuse. Unplug other equipment
using the same circuit. Make sure
cords are plugged into proper amp
circuits.
PROBLEM
POSSIBLE CAUSE
HOW TO REPAIR
Switch is turned on, power is
intermittent to all motors
1. Faulty electrical cable
1. to 3.: See autohrized repair person
2. Defective switch
3. Loose terminal or corroded connector
Electric shock
1. Equipment or electric cord not
grounded
See authorized repair person
Pump motor stopped
1. Pressure build up cause by jet clogged.
1. Released pressure by opening up
(press) the lever on the Wand.
2. Thermal overload (over heated)
2. Turn off the pump and heater
switch and wait 20-30 minutes
3. Damaged motor or rectifier
3. to 7: See authorized repair person
4. Pump switch defective
5. Loose wire connection
6. Pump pressure switch defective
7. Faulty motor
Loss of pump presure with wand
valve open and/or uneven or weak
spray from the jet tips
1. Clogged or dirty spray tip
1. Clean jets and screens
2. Accumulated dirt in solution line
2. Flush system w/water
3. Dirty or clogged filters
3. Clean
4. Pump check valve worn or dirty
4. to 6: See authorized repair person
5. Malfuction in the wand valve
6. Hose quick connect bad or clogged
with foriegn object