Safety, Operation and Maintenance Manual for Eagle (RA 700 B / RA 701 B);
6
BEFORE USING THE AUTO-SCRUBBER (cont.)
CHARGING THE BATTERIES
•
Turn machine off with the key switch and
main switch.
•
Empty recovery tank completely and tilt
sideways.
•
Remove charging plug from machine.
•
Connect cable of charger with battery cable.
•
Turn-on battery charger.
•
Turn main switch on (D8).
When using gel batteries (maintenance free) the waste water tank can be left closed
during the charging process. Using wet batteries (lead-acid batteries), the waste water
tank must be kept tilted OPEN during the entire charging process.
ATTENTION! The manufacturer takes no responsibility when battery spills occur!
PREPARATIONS FOR WORK
Depending on the type of operation the machine must be equipped respectively with the correct brushes
or pad drivers and pads.
•
Fix squeegee assembly (A6) into holder for
squeegee.
•
Fix with the two locking levers (D2).
•
Connect vacuum hose (D7) from the
squeegee (A6) to the vacuum hose
connection (D9) at the recovery tank.
•
Lower the squeegee with lever (D5).
•
Lower brushes (A4) by using the foot lever
(D1).
The controls have universal symbols for the function they control.
•
Fill the solution tank with clean water and
add the chemical required for the specific
task (Follow directions for dilution). The
maximum capacity of the solution tank is 23
gallons (US).
•
Set the solution flow rate with the flow button
(A7). After each use set the flow rate back to
“0”.
FUNCTIONAL PARTS AND ACCESSORIES
A. General
view
1. Controls/handle
2. Dome of recovery tank
3. Solution tank
4. Brush housing
5. Drive wheel
6. Squeegee assembly
7. Water flow valve
B. Controls
1. Vacuum
switch
2. Brush
switch
3. Solution switch, standard volume on/off
4. Drive lever / safety lever
(squeeze to drive)
5. Reset
switch
6. Switch for reverse
7. Control light for recovery tank water
level
8. Key
switch
9. Speed control knob
C. Solution and recovery tank
1. Solution tank
2. Recovery tank
3. Dome and vacuum intake filter
4. Solution tank cover
D. Rear
view
1. Foot lever to raise/lower brushes
2. Squeegee locking lever
3. Clamp for fixation of squeegee
4. Screw for squeegee angle adjustment
5. Lever to raise/lower squeegee assembly
6. Recovery tank drain hose
7. Vacuum hose
8. Main switch
9. Vacuum hose connection
10. Solution tank drain valve