- 13 -
5
5
5
5 Troubleshooting
Troubleshooting
Troubleshooting
Troubleshooting
Problem
Possible Cause
Solution
Pump can
not start
power failure
Check the power supply
The fuse blowouts
Change fuse
Circuit is interrupted.
Find the off position
Wrong connecting wire
Recheck the diagram
Pipe blockage
Open the valve, and clean it
No Flow
Not work
Check the power
Offering tank is empty
Fill the tank
Pipe blockage
Clean the pipe
Valve is closed
Open the valve
Granule block off check
valve
Check the valve and clean it
Air in the pipe
Release the air
Cavitations
Increase the pressure of suction and
shorten the suction pipe.
Problem of priming
Re-priming, checking leakage
Filter is blocked
Disassemble the filter; clean or
change it.
Adjust
the
stroke
to
zero.
Increase stroke length.
Low flow
Valve broken or serious
dirty.
Clean the valve or clean it.