![Clean Water Systems 7500-S1 Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/clean-water-systems/7500-s1/7500-s1_installation-manual_2620087013.webp)
7500-S Sediment Filter Installation & Startup Guide
Page 4
www.cleanwaterstore.com
Rev 083016
Set Days Between Backwash
Display will read 1 – 01. Press the Menu/Confirm button and days will flash. Using the up or
down arrow adjust to number of Days between Backwash.
For Sediment Backwash filters, we recommend 4 – 6 days. This can be changed later. If you
find you have pressure loss (meaning the sediment filter material needs backwashing) adjust to
more frequent backwashes up to 1 per day.
Press the Menu/Confirm button.
Press the Scroll Down button to continue, F – 00 will display.
Set Number of Consecutive Backwash Cycles (not used)
Leave at F – 00. If you ever wanted the filter to go into another backwash/rinse cycle
immediately following a backwash/rinse cycle, this can be set to F – 01. However, this is rarely
used and a single backwash and rinse regeneration cycle is usually enough.
Press the Scroll Down button to continue, 2 – 10 will display.
Set Length of Backwash Cycle
2 – 10 refers to the minutes the system will go into or be in backwash mode. Leave this at 10
but can be set to 8 or increased to 12 or 14 etc if a shorter or longer backwash is desired.
To change Press the Menu/Confirm button and using up or down arrows adjust the minutes.
Press the Scroll Down button to continue, 3 – 10 will display.
Set Length of Rinse Cycle
3– 10 refers to the minutes the system will go into or be in rinse to drain mode (after backwash
cycle). This can be set to 8 minutes. To change Press the Menu/Confirm button and using up
or down arrows adjust the minutes.
Press the Scroll Down button to continue, b ‐ 01 will display. Press the Menu/Confirm button.