![CLEAN ROOM DEVICES CRD600 Скачать руководство пользователя страница 8](http://html.mh-extra.com/html/clean-room-devices/crd600/crd600_operation-manual_2620055008.webp)
8
2.3 Pin Set Installation
(Air supply must be disconnected)
Remove the magazine from the unit and loosen the six button head screws on both sides
of the cover. Lift up the cover and carefully place on left side of base as wire and air
lines are connected from cover to unit.
The CRD600 is equipped with a Pin Set Assembly which is designed for a specific tube
fitting.
Roll the pin on a flat surface to insure that it is straight.
Insert the pin tip into the hole near the bottom of the magazine rack. Slide the pin
through the hole until it is horizontal within the CRD600 (Shown in figure 3 below).
Push the pin toward the back of the unit until the threaded end reaches the threaded
cylinder rod. Turn the pin clockwise to tighten.
Ensure both threaded parts are clear
of any sand or other particulates, as a crooked pin can cause severe damage to the
CRD600.
Once the pin is hand-tightened, pull the pin forward exposing the cylinder (Shown in
figure 4 below). Place a wrench on the flats of the cylinder rod and hold in place.
Place the 5/16” open end wrench onto the flats of the pin set and turn to secure the pin
into the cylinder rod (Shown in figure 5 below).
Manually pull the pin forward to ensure it goes through the magazine and into the jaw
set.
Figure 3 - Aligning the pin Figure - 4 Threading pin to cylinder Figure - 5 Tightening pin to cylinder