![CLEAN ROOM DEVICES CRD600 Скачать руководство пользователя страница 12](http://html.mh-extra.com/html/clean-room-devices/crd600/crd600_operation-manual_2620055012.webp)
12
If a fitting is properly seated in the magazine, the sensor will detect this and display a
Amber LED as well as the single green ‘power on’ LED. Shown in the figures below is
the sensor with and without fittings.
THIS SENSOR’S POSITION IS A FACTORY SETTING, ANY ADJUSTMENT
COULD CAUSE DAMAGE TO YOUR PIN SET, MAGAZINE OR JAW SET.
Figure 7 - Sensor without fittings Figure 8 - Sensor with Fittings
Adjusting Last Fitting Sensor Position –
By adjusting the sensor up or down, you can position the
sensor properly. Using five (5) thin strips of paper, make a spacing gauge for the Last Fitting Sensor.
(Figure 9)
Figure 9 – Unit with 5 strips of paper
Figure 9.1 – Verifying LFS light “ON”
When four (4) strips of paper are inserted between the magazine and the top of the magazine rack,
the Last Fitting Sensor light should be on. (Figure 9.1)
Fitting detected
Sensor Power
Last Fitting
Sensor Light
On
Four (4) strips
of paper