4. Before Use

4.1.   Check before use

Check before every use:

• 

that individual parts, particularly the air hose and 

sealing elements, are not apparently damaged,

• 

that the hose is fitted correctly to the unit and to 

the head part connector,

• 

that the air pressure in the distribution system 

is in the range 300 to 1000 kPa (for both CA 

Pressure and CAP Conditioner),

• 

that the air flow in the hose is sufficient (using 

the air flow indicator, see Chapter 4.2.),

• 

that air is supplied from the head part.

4.2.  Air flow test (CA Pressure / CA Flow Master)

All units are pre-adjusted on the airflow of 170 liters/

min. When measuring the airflow, follow the instruc-

tions in the manual enclosed to the flow indicator. If 

the flow rate is different, proceed as follows:

1.  Pull the reducing valve, you will hear a click. see. 

pictorial annex 2A.

2.  To set the optimal airflow, rotate the reducing val-

ve clockwise or counter-clockwise (to check the 

airflow, you may conect flow meter) see. pictorial 

annex 2B.

3.  Push the reducing valve, you will hear a click (see. 

pictorial annex 2C).

WARNING: 

The airflow should not drop below 160 liters/min!

5. Maintenance and Cleaning

CA Pressure (Flow Master)

Every time you finish work, it is recommended to cle-

an the CA Pressure unit, to check individual parts and 

to replace the damaged ones.

•  Cleaning must be carried out in a well ventilated 

room. Avoid inhaling the harmful dust settled on 

individual parts of the unit and accessories!

•  It is forbidden to use cleaning agents containing 

solvents or abrasives. Detergents are recommen-

ded.

•  The air hose can be rinsed with clean water.

•  Use a damp cloth for cleaning. Each part must be 

wiped dry after cleaning.

CA Pressure Conditioner 

•  Once a week, drain the condensate from the con-

tainer bottom by the cock located on the bottom  

side. Before this operation, it is recommended 

disconnecting the unit from the compressed air 

supply.

•  Replace the filter at least once in three months. 

After this period, viruses and bacteria may proli-

ferate in the unit filter and if it is used regularly, 

the absorption capacity of the activated carbon 

eliminating smells may be exhausted (if the air lea-

ving CA Pressure Conditioner smells in any way, 

replace the filter immediately). 

•  When replacing the filter, clean the inner part of 

the container with a dry cloth or detergent.  

6. Spare Parts and their

    Replacement

6.1. 

Filter for CA Pressure Conditioner

The filter plant CAP Conditioner contains a combined 

filter which removes oil mist, smells and flavours from 

industrially produced compressed air.

The filter does not remove CO and CO

2

!

Read the instructions for use and replacement.

 

Replacing CA Pressure Conditioner filter:

See pictorial annex 3A-3C

•  Unscrew the top part of the filter pressure contai-

ner (6 screws).

•  Remove the contaminated filter, wipe the inside of 

the container.

•  Check the condition of the rubber seal in the top 

cover. If the seal is damaged, replace it.

•  Install a new filter, put the container cover on and 

screw it back.

•  Check the container for leakage. If the container is 

not absolutely tight, tighten all screws that fasten 

the top cover.

7. Storage

If any fault, sudden decrease or increase in air supply 

occurs and the user is at a contaminated workplace, 

it is necessary to leave the workplace and to check 

the following:

•  That the unit is assembled correctly.

•  The filter condition in CA Pressure Conditioner.

•  That the air hose is not damaged. It is necessary 

to make sure that, during work, the hose is not got 

caught at projecting objects and a crack cannot 

occur.

•  That the noise damper in CA Pressure is not 

clogged.

•  That the seal on the safety hood is in good con-

dition. All components of CleanAIR® systems must 

be stored in rooms with temperatures between 

0 °C and 40 °C with relative air humidity between 

20 % and 80 %. The storage time in closed con-

tainers is max. 2 years, except for the batteries!.

8. Warranty

Warranty for manufacturing defects is 12 months from 

the date of sale to the customer. A claim must be filed 

with the sales organization and the proof of sale (in-

voice or delivery note) must be submitted.

Warranty does not cover in particular defects caused 

by a late replacement of the filter or by using a filter 

damaged by cleaning or blowing.

Содержание Pressure

Страница 1: ...CleanAIR Pressure Flow Master CleanAIR Pressure CleanAIR Pressure Conditioner NA 013 R03 GER X NOR X RUS X SPA X SWE X ENG 3 CZE X DUT X FIN X FRE X PERSONAL RESPIRATORY PROTECTION SYSTEMS USER MANUAL ...

Страница 2: ......

Страница 3: ...ove carbon monoxide CO and carbon dioxide CO2 from the air 1 1 Requirements for compressed air supplied from the compressor CA Pressure Conditioner can only be connected to compressor which supplies air at an oxygen con centration of 20 to 22 vol The carbon dioxide concentration must not exceed 500 ppm and the carbon monoxide concentration must not exceed 15 ppm The maximum concentration of water ...

Страница 4: ...re breached the warranty becomes null and void 3 Unpacking Assembly Use and Functions 3 1 Unpacking CA Pressure Check that the delivery is complete and no damage occurred during transport Content of the CA Pressure 63 00 00 CA Pressu re Flow Master 67 00 00 contain CleanAIR Pressure Flow Master unit 1 pc Belt for the unit 1 pc Air flow indicator 1 pc User manual 1 pc Content of the CA Pressure Con...

Страница 5: ...r and if it is used regularly the absorption capacity of the activated carbon eliminating smells may be exhausted if the air lea ving CA Pressure Conditioner smells in any way replace the filter immediately When replacing the filter clean the inner part of the container with a dry cloth or detergent 6 Spare Parts and their Replacement 6 1 Filter for CA Pressure Conditioner The filter plant CAP Con...

Страница 6: ...otified body for CE testing Výzkumný ústav bezpečnosti práce v v i ZL Testing Laboratory No 1024 Jeruzalémská 9 116 52 Praha 1 Authorized Body 235 Notified Body 1024 6 The unit does not supply the sufficient amount of air Air hose or air channel blocked Check and remove the possible ob stacle Air escapes through leakages Check all sealing elements and co nnections check that the hose is not damage...

Страница 7: ...r Order No Description 63 00 00 CA Pressure belt 67 00 00 CA Pressure Flow Master comfort belt 61 00 30 Standard hose 10 m for CAP 61 00 38 Standard hose 25 m for CAP 61 00 39 Standard hose 50 m for CAP 61 00 46 Spiral hose 10 m for CAP mechanically resistant mod 63 00 10 CA Pressure silencer 70 00 60 Light flexi hose CA40x1 7 CA40x1 7 70 00 86CA Rubber hose CA40x1 7 CA40x1 7 70 00 95 Belt for CA ...

Страница 8: ...ičitý CO2 1 1 Požadavky na stlačený vzduch přicházející z kompresoru CA Pressure Conditioner může být připojen pouze na kompresor distribuující vzduch s procentuelním zastoupením vzduchu 20 až 22 Koncentrace oxidu uhličitého nesmí překročit 500 ppm a kon centrace oxidu dusného nesmí překročit 15 ppm Koncentrace vody ve vzduchu by neměla překročit 50 mg m při jmenovitém tlaku vzduchu v rozmezí 1 20...

Страница 9: ...rétnímu produktu Pokud je kterýkoli z uvedených principů v tomto manuálu porušen záruka zaniká 3 Rozbalení montáž funkce a použití 3 1 Rozbalení CA Pressure Zkontrolujte že dodávka je kompletní a nedošlo k žádnému poškození při přepravě Obsah balení CA Pressure 63 00 00 a CA Pressure Flow Master 67 00 00 obsahuje Jednotka CleanAIR Pressure Flow Master 1 ks Opasek 1 ks Indikátor průtoku vzduchu 1 k...

Страница 10: ... být utřena do sucha CA Pressure Conditioner Jednou za týden vypusťte zkondenzovanou vodu vodu z nádrže za pomoci výpusti umístěné na spodní části Před tímto úkonem je doporučeno odpojit jednotku od zdroje stlačeného vzduchu Vyměňte tento filtr vždy alespoň jednou za 3 měsíce Po uplynutí této doby se mohou v jednotce začít velmi rychle množit viry a bakterie V případě že je jednotka používána prav...

Страница 11: ...pro testování CE Výzkumný ústav bezpečnosti práce v v i ZL Testovací laboratoř č 1024 Jeruzalémská 9 116 52 Praha 1 Autorizovaná osoba 235 Notifikovaná osoba 1024 11 Jednotka neposkytuje dostatečné množství vzduchu Hadice nebo vzduchový kanál jsou ucpané Zkontrolujte a odstraňte případné překážky Vzduch uniká díky netěsnostem Zkontrolujte všechny těsnící elementy a spoje a prověřte zdali není hadi...

Страница 12: ...e Flow Master Objednací č Popis 63 00 00 CA Pressure belt 67 00 00 CA Pressure Flow Master comfort belt 61 00 30 Standard hose 10 m for CAP 61 00 38 Standard hose 25 m for CAP 61 00 39 Standard hose 50 m for CAP 61 00 46 Spiral hose 10 m for CAP mechanically resistant mod 63 00 10 CA Pressure silencer 70 00 60 Light flexi hose CA40x1 7 CA40x1 7 70 00 86CA Rubber hose CA40x1 7 CA40x1 7 70 00 95 Bel...

Страница 13: ...13 CA Pressure conditioner assembly 1A Airflow adjustment CA Pressure CA FM 2A 2B 2C ...

Страница 14: ...hangable silencer Airflow regulation Reducing Valve Pressure hose connector Headtop CA 1 CA 2 CA 3 CA 4 CA 10 CA 20 CA 40 G GW CA 28 Euromaski Unit CA Pressure 2A 2A 2A 2A x x 2A 2A CA FM 2A 2A 2A 3A 2A 3B 2B 2A Possible combinations Hose connector ...

Страница 15: ...15 ...

Страница 16: ...16 ...

Страница 17: ...MALINA Safety s r o Luční 11 466 01 Jablonec n Nisou Czech Republic Tel 420 483 356 600 Fax 420 483 312 106 export malina safety cz www malina safety com ...

Отзывы: