CLEANING AND MAINTENANCE 

4

Bi-Polar Ionization System 

(Recommended Clean, as needed)

If the device produces a creaking sound, use a 

brush pen as a cleaning tool. Regularly clean 
dust around the bi-polar ionization system. 

5

Particle Sensor

(Recommended Clean, every 2 months)

Please ensure the power is disconnected before 

cleaning. Use a dry cotton swab to clean the lens 
regularly to remove moisture and dust. Remove the 

outer cover of particle sensor (Fig. 1). Use the dry 
cotton swab to clean the lens (Fig. 2).  

1

Pre-Filter 

(Recommended Clean, every 15 days)

Use a vacuum cleaner to clean the dust 
from the surface of the screen, or wash 
with water and dry thoroughly.

2

Cellular-Activated Carbon Filter 

(Recommended Clean, every 2 months)

Use a vacuum cleaner to clear the dust on 

the surface of the screen. Place the filter 

into a well-ventilated place. Do not expose 
it to strong sunshine. Be gentle when 

cleaning and touching the filter. Do not 
use water to clean this filter.

3

Antibacterial/HEPA filter 

(Recommended Clean, every 2 months)

Place the filter in a well-ventilated area 

and do not expose it to strong sunshine. 

Do not use water to clean this filter.

NOTE: 

Be sure to disconnect the power before cleaning and maintenance. Do not open the device when filters have been removed. Please unplug 

the power if the device will not be in use for an extended period of time. According to the use of places and methods (i.e., a household with smokers 

or a place with serious pollution), the filter life will be shortened. In these instances, please replace the filter more frequently.

(Recommended Replace, every 12 months)

Never stare at or expose skin to UV light bulb 

while the device is operating.

6

UltraViolet Sterilizer Bulb

Содержание AtmosAir Everest

Страница 1: ...lth and wellness by actively restoring indoor air to its pure natural state where no pollution or contaminants exist while reducing energy use and emissions in the process AtmosAir com CAG 06 21 001 IMPORTANT Save this Document for Future Reference Warranty Information ...

Страница 2: ... bi polar ionization air purification technologies that actively continuously work to bring the benefits of improved air quality to life in all types of built environments Every day AtmosAir is helping the world to see air differently with solutions that measure validate and display real time indoor air quality data and deliver ongoing tangible benefits to human health and productivity AtmosAir te...

Страница 3: ...ents 01 HOW IT WORKS 1 02 PRODUCT OVERVIEW 2 03 INSTALLATION PROCEDURES 3 04 EVEREST CONTROLS OVERVIEW 4 05 SETTINGS 5 06 INSTALLATION NOTICE 6 07 SAFETY PRECAUTIONS 7 08 CARE CONSIDERATION 8 09 CLEANING AND MAINTENANCE 9 10 FILTER REPLACEMENT PROCEDURES 10 11 TROUBLESHOOTING 11 12 PRODUCT WARRANTY 12 ...

Страница 4: ...rtains bedspreads plywood and wallpapers Honeycomb Activated Carbon Filter The Honeycomb Activated Carbon Filter offers absorption of VOC s and other gases contaminatnts and in combination with all of the other technologies helps to make the product more efficient Antibacterial Filter The Antibacterial Filter can target contaminants such as bacteria spores and other microorganisms and help to reus...

Страница 5: ... 02 PRODUCT OVERVIEW Circuit Diagram Side View Top Side Control Panel Handle Air Outlet Air Inlet Front Panel Control Panel Rear Side UV Lamp Display Panel Front Panel remove switch Touch Panel PCB Main PCB Fuse Anti fall off switch Live wire Neutral wire Sensor Ionizer Motor Air Inlet ...

Страница 6: ...Open the cover Install filter 3 Antibacterial HEPA compound filters Note Please ensure the tab side is facing you Install filter 2 Cold Catalyst Activated Carbon removal compound filters Note Please ensure the tab side is facing you Install filter 1 Pre filter Note Please ensure the handle side is facing you Install front panel Take out the filters Remove all packaging material ...

Страница 7: ... device into auto mode and an auto indicator displays on the panel With this mode automated cleaning begins based upon the degree of air pollution and the air volume will automatically adjust Low speed PM2 5 60 Medium Speed 60 PM2 5 150 High speed PM2 5 150 Pressing the sleep button enables sleep mode and the display panel and light will turn off The motor in this setting only works at low speed A...

Страница 8: ...olled operation Simply press time and set the device operating time A countdown will run and then stop automatically after time has run out To cancel the timer press and hold timer for 3 seconds To set the time press the auto button for 5 seconds Time will display Hour digits will flash first press the speed button to add 1 press the sleep button to subtract 1 Set Hour and then press the auto butt...

Страница 9: ...erference 2 For mitigating pollen and other indoor dust This device should be placed on a flat surface on the ground Pollen dust and other contaminants easily fall to the floor and can be absorbed 3 In order to effectively circulate air in the room There should be a gap of at least 8 inches around both sides and the back of the device There should be a gap of at least 12 inches from the top surfac...

Страница 10: ...o not let water flammable detergent or other liquid into the device as this may cause shock hazard or damage beyond reapir 7 This device is not intended to replace cooking hoods or industrial type applications 8 Do not operate this product near gas appliances heating devices or stoves 9 Do not operate this product within a humid or high temperature environment i e bathroom toilet or kitchen 10 Do ...

Страница 11: ...y anomalies or malfunctions that occur 5 Using the power cord to pull off the plug from the power cord may cause power cord damage shock hazard short circuit or damage beyond repair Disclaimer The air purification technologies provided by Clean Air Group are intended to improve indoor air quality They are not intended as a replacement for reasonable precautions aimed at preventing the transmission...

Страница 12: ...an every 2 months Use a vacuum cleaner to clear the dust on the surface of the screen Place the filter into a well ventilated place Do not expose it to strong sunshine Be gentle when cleaning and touching the filter Do not use water to clean this filter 3 Antibacterial HEPA filter Recommended Clean every 2 months Place the filter in a well ventilated area and do not expose it to strong sunshine Do...

Страница 13: ...days It is suggested to replace this filter every 2 years 2 Cellular Activated Carbon Cold Catalyst Filter It is suggested to maintain the Cellular Activated Carbon Cold Catalyst Filter every 60 days It is suggested to replace this filter every 6 months 3 Antibacterial HEPA Filter It is suggested to maintain the Antibacterial HEPA filters every 60 days It is suggested to replace this filter every ...

Страница 14: ...central enough to easily absorb air If so change the place 2 Is the particle sensor dirty If so clean the sensor Sound can be heard during operation Clean the bi polar ion emitters There may be too much dust The smell of the outlet gives an uncomfortable feeling 1 Is the filter dirty If so clean the filter 2 Has the filter not been changed in a while If not replace the filter with a new one The de...

Страница 15: ...F CLEAN AIR GROUP HERIN ARE EXPRESSLY GRANTED IN LIEU OF ALL WARRANTS WHETHER EXPRESS OR IMPLIED INCLUDING BUT NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ALL IMPLIED WARRANTIES INCLUDING WARRANTIES OF MERCHANTABILITY AND FITNESS FOR PARTICULAR PURPOSE ARE LIMITED TO THE TERM OF THE EXPRESS WARRANTY GRANTED HEREIN Some states do not allow limitations o...

Отзывы: