Repair or Warranty Contact
Clayton Associates, Inc.
•
1650 Oak Street
•
Lakewood, New Jersey 08701
•
P.+1-732-363-2100 F.+1-732-364-6084
www.DustlessMadeSimple.com
•
Page 7
4. Attach the Grounding Cable
• This is required only if the vacuum will be used in the presence of combustible dust
• The grounding cable included should be plugged into the grounding jack and clamped to either the work piece or the same grounding
point as the work piece.
5. Attach the Compressed Air Line
Clayton EXP compressed airlines are conductive and provide compressed air to power the vacuum and as a drain for static buildup
This equipment is only validated for dust ignition proof operation when used with this airline
• Ensure that the compressed air valve on the vacuum is in the off position
• Connect the compressed airline to a compressed air source
• Connect the compressed airline to the compressed air plug on the vacuum
6. Attach the Vacuum Hose
Clayton EXP vacuum hoses are conductive and provide a drain for static buildup
This equipment is only validated for dust ignition proof operation when used with these vacuum hoses
Vacuum Hose only
• Open the Vacuum Inlet
• Insert the metal sleeve of the vacuum hose into
the inlet on the vacuum
Combination Air/Vac Hose
• Open the Vacuum Inlet
• Insert the metal sleeve of the vacuum hose into the
inlet on the vacuum
• Connect the compressed airline to the compressed
air coupler on the vacuum
7. Activating the Vacuum
Rotate the compressed air valve on the vacuum
90 degrees counter-clockwise to start compressed
air flowing and activate the vacuum
Grounding Cable
BEFORE EACH USE
Grounding Jack
Compressed Air Line
Vacuum Hose
Compressed
Air Line
Compressed
Air Valve On
Compressed
Air Valve Off
Vacuum Inlet
Compressed
Air Coupler