G3 Display 006 – 00001GF User’s manual
006-00001DSF rev.002 Clayton Power R&D, s.r.o.
5
J1
Pin
Signal
Description
1
2
3
4
5
6
7
8
9
10
11
12
GND
GND HALL
+5V HALL
REMOTE OUT
+BATTERY
DATA
OUT_1
OUT_2
OUT_3
SNS HALL
INPUT_1
INPUT_2
Supply ground ( - BATTERY)
Hall sensor ground
Hall sensor supply
Remote control of G3
Supply voltage (+ BATTERY)
Single Wire Data communication
Output #1 – Generator remote control
Output #2
Output #3
Hall sensor output
Input #1
Input #2
J4, J5
Pin
Signal
Description
1
2
3
4
5
6
-TEMPX1
GND_TELE
+TEMPX1
SYNC_IN/OUT
DATA
REMOTE OUT
N/A for Display
User’s GND (Fused)
N/A for Display
N/A for Display
Single Wire Data communication
Remote control of G3
Mating connector type is
Connectors J4 and J5 are connected in parallel.