-Trig Voltage – generator trigger voltage; if the battery voltage is bellow this voltage,
the generator is turned on. The Generator cannot be turned on while the battery
voltage is below the trigger level.
Max Time – maximum period of time the generator is allowed to run if the combi is
unable to fully charge the battery within this time. The timer will start to run when the
battery voltage is above the voltage trigger level.
Manual Cont. – manual control of generator. Generator can be controlled manually
from trigger voltage until the battery is detected full.
While battery voltage is below Voltage trigger level it is not possible to stop the
Generator and while the battery is detected full the generator will be stopped
automatically.