background image

INDEX 

1. APPLICATIONS ........................................................................................................................................... 1 

2. PUMPABLE LIQUIDS .................................................................................................................................. 1 

3. TECHNICAL DATA AND LIMITATIONS OF USE ...................................................................................... 1 

4. MANAGEMENT ............................................................................................................................................ 2 

4.1  Storage ................................................................................................................................................ 2 

4.2  Transport ............................................................................................................................................... 2 

4.3  Weight and dimensions ....................................................................................................................... 2 

5. WARNINGS .................................................................................................................................................. 2 

6. INSTALLATION ........................................................................................................................................... 2 

7. ELECTRICAL CONNECTION ...................................................................................................................... 3 

8. START-UP .................................................................................................................................................... 3 

9. PRECAUTIONS ............................................................................................................................................ 3 

10. MAINTENANCE AND CLEANING ............................................................................................................ 3 

10.1 Cleaning the suction grid ...................................................................................................................... 4 

10.2 Cleaning the impeller ............................................................................................................................ 4 

11. TROUBLESHOOTING ............................................................................................................................... 4 

12. GUARANTEE ............................................................................................................................................. 4 

WARNINGS 

&

Read 

documentation 

before installation: 

1. APPLICATIONS

all 

this 

carefully 

&

Take  out  the  plug  before  any  intervention.  Absolutely  avoid  dry 

operation:  the  pump  must  be  activated  exclusively  when  it  is  immersed  in 

water.  If  the  water  is  finished,  the  pump  must  be  deactivated  immediately, 

taking the plug out of the socket. 

The pumps are of the submersible type,  designed and made for pumping cloudy water without fibres,  for domestic uses,

with manual or automatic operation,  for drying basements and  garages  subject to flooding,  for pumping drainage wells,

pumping rainwater collecting traps or infiltrations from roof gutters, etc.

Thanks  to  their  compact  and  handy  shape,  they  are  also  used  for  particular  applications  as  portable  pumps  for

emergency  situations  such  as  for  drawing  water  from  tanks  or  rivers,  draining  swimming  pools  and  fountains,

excavations or underpasses. Also suitable for gardening and general hobby activity.

&

These pumps cannot be used in swimming pools, ponds or basins where people are present, or for 

pumping  hydrocarbons  (petrol,  diesel  fuel,  combustible  oils,  solvents,  etc.)  in  accordance  with  the 

accident-prevention  regulations  in  force:rhey  are  not  designed  for  continuous  use,  but  for 

emergency  use  over  a  limited  period.  They  should  be  cleaned  before  putting  them  away.  See  the 

chapter "Maintenance and Cleaning". 

2. PUMPABLE LIQUIDS

Fresh water
Rainwater
Clear waste water

Dirty water
Foul waste water containing solid bodies with long fibres
Fountain water
River or lake water
Max. particle dimension [mm]

Suitable

o

Not suitable

• 

• 

• 

• 

• 

• 

030 

Table1 

The pump is watertight and must be immersed in liquid to a maximum depth of 7m.  See Table 3. 

3. TECHNICAL DATA AND LIMITATIONS OF USE

The pump unit is only to be installed in an electrical supply conforming to  Australian  Electrical 

Regulations 2002. This must include a l�n = 30mA safety switch. All electrical installations are to be 

performed by a Licensed Electrician. 

Содержание EcoSub 7

Страница 1: ...INSTRUCTIONS FOR INSTALLATION AND MAINTENANCE EcoSub 7 ...

Страница 2: ...Fig 1 3 a b 5 7 i c I a b c a 2 4 6 I I r If 8 j d ...

Страница 3: ...are also used for particular applications as portable pumps for emergency situations such as for drawing water from tanks or rivers draining swimming pools and fountains excavations or underpasses Also suitable for gardening and general hobby activity These pumps cannot be used in swimming pools ponds or basins where people are present or for pumping hydrocarbons petrol diesel fuel combustible oil...

Страница 4: ...d dimensions The adhesive plate on the packaging indicates the total weight of the pump and its dimensions 5 WARNINGS The pumps must never be carried lifted or allowed to operate suspended from the power cable use the handle provided The pump must never be allowed to run when dry On the body there is a venting hole to avoid phenomena of cavitation when starting the pump It is therefore normal for ...

Страница 5: ...know the minimum starting and stopping height see the Technical Data chapter The cable length must on one hand allow the float switch to move freely and on the other prevent it resting on the bottom The portion of cable between the float switch and the cable stay notch must not be less than 10 cm long The shorter the portion of cable between the float switch and the cable stay notch the lower will...

Страница 6: ...ted does not start B Check the protection fuses and does not C The switch is not activated by the float B If burnt out change them make any noise lf bumt out change them Place it facing up Increase the depth of the trap The pump does A The suction grid or the pipes are blocked A Remove the obstructions or straighten 2 not deliver flow B The impeller is worn or blocked the hose if it is twisted C T...

Страница 7: ...med by non approved personnel may void the warranty To make a claim contact Clayton Engineering 26 French Ave Brendale 4500 on phone 1300 798 022 or email sales claytonengineering com au You will be asked to provide proof of purchase and then will be instructed on the procedure for repairing or replacement of the product under warranty All costs incurred for repair or replace and additional claims...

Страница 8: ...in this document are subject to trademark patent or design registrations Infringement of any intellectual property contained within this document without express written authority by the appropriate intellectual property holder may result in further legal action to be taken For any queries regarding use of the contained information please feel free to contact White International Pty Ltd WHITE INTE...

Отзывы: