31
• LAMP CONTROL (only with option LDmx On) - channel: 17
IMPORTANT: Alpha Spot 300 is not provided with hot restrike igniter
LAMP ON
LAMP ON
BIT
%
EFFECT
255
100
180
70.5
0
0.0
101
39.5
ON
ON
OFF
100
39.0
LAMP OFF
179
70.0
26
10.0
LAMP OFF
25
9.7
OFF
UNUSED RANGE 1
UNUSED RANGE 2
The function is activated
staying 5 s in Lamp ON levels.
The function is activated
passing throug the unused
range 1 and staying 5s in
Lamp OFF levels.
• RESET - channel: 16
BIT
%
EFFECT
255
100
128
50.0
127
49.7
77
30.0
76 29.7
26 10.0
25
9.7
0 0.0
Complete reset is activated passing
throug the unused range and staying
5 seconds in complete reset levels.
COMPLETE RESET
PAN / TILT RESET
PAN / TILT RESET
EFFECTS RESET
EFFECTS RESET
UNUSED RANGE
Pan / Tilt reset is activated passing
throug the unused range and staying
5 seconds in Pan / Tilt reset levels.
Effects reset is activated passing
throug the unused range and staying
5 seconds in Effects reset levels.