41001476 Iss 01
ENSURE THE AIR OUTLET OF HE7230 AND
HE7245 IS NEAREST TO THE WALL OR CORNER.
3.1 Installation
It is the sole responsibility of the installer to en-
sure that the points of attachment to the building
are sound. Care must be taken to allow complete
free air movement into the inlet grilles of the unit to
ensure the correct working operation of the heater.
Carefully unpack the unit. The unit is supplied with
a length of self-adhesive foam strip. This can be
cut into lengths and is to be laid on the 4 sides of
the bottom of the heater casing . This will ensure
that the unit assembly is free from vibration.
The weight of the HE7237SL/RX, HE7247SL/RX is
12kg
The weight of the HE7267SL/RX is 15kg
-
Split and remove shroud
A pair of machine screws hold each shroud half
together at each joint. A machine screw secures
each shroud half to each appliance beam. Re-
move these machine screws and slide each
shroud half off the appliance base panel. The
base panel fits inside the shroud halves.
The diffuser is already clipped into and under the
base panel and need not be removed.
- Hanging Rod Positions
With the shroud removed the two appliance
beams reveal the holes/slots shown and dimen-
sioned below. It is required that two 10 mm
hanging rods (stud bars) support each appliance
beam. The rods pass through and into
each appliance beam. Support washers
together with nuts locate and lock the
appliance beams after adjustment to
level the appliance.
- Replace Shroud Halves
The reverse of above. Slide shrouds
beneath and around base panel. Se-
cure each shroud half to each appliance
beam with machine screws. Screw
shroud halves together at each joint.
4.1 Electrical Connections.
These units are suitable for connection
to a 230/240 Volt 50 Hz single phase
supply.
The appliance shall be connected to the
supply via an appropriate switched fused double
pole isolator having a contact separation of great-
er than 3mm. Test for correct operation and refit
the cover.
3. Installation Details.
Fig.1 Air discharge of HE7237SL/RX and
HE7247SL/RX
Fig.2 Air discharge of HE7267SL/RX
For connection to the mains supply it will be
necessary to open the terminal cover at the side/
back of the unit to connect the supply from the
controls prior to refitting the cover. Wire in accord-
ance to the wiring diagrams.
For safety reasons, a sound earth connection
must always be made to the unit before it is put to
use. The unit should be wired in accordance with
IEE Regulations for the Electrical Equipment of
Buildings.
4. Electrical Connections.
Fig.3 Heater assembly
SUSPENSION POINTS
TERMINAL COVER
TOP OR SIDE CABLE ENTRY