4. Electrical Connections.
4.2 Electrical connections for standard models
Fig.6 Mains supply via remote switch
N
L
E
N and E connected by 30A
one way connector block
Fig.7 Wiring of the heaters without using remote switch
4.3 Electrical connections without using the remote switch standard models
If the heaters are to be controlled by means other than the remote switch supplied, eg BMS, then
the heat output can be selected by connecting the appropriate terminals.
WIRED TERMINALS
HE7230
HE7245
HE7260
H1 + H2 + F
3000W
4500W
6000W
H1 + F
1000W
1500W
2000W
H2 + F
2000W
3000W
4000W
Please note the ‘F’ terminal must always be connected
F - Fan
H1 - Heating element 1
H2 - Heating element
N - Neutral
E - Earth
41001456 Iss 01
Fig.5 Remote switch terminal side view
Fig.4 Mains supply direct to heater
N L
E
L
L
L connected by 30A
one way connector block
L
L
L1
Two independent live
feeds must be used on
4,5kW and 6kW heaters as
shown on the diagrams