ENSURE THE AIR OUTLET OF HE7230 AND 

HE7245 IS NEAREST TO THE WALL OR CORNER.

 

3.1  Mounting 

 
The  Claudgen  recessed  ceiling  heaters  are  de-
signed to fit in place of a standard 600mm ceiling 
panel. 
 

IT  IS  ESSENTIAL  THAT  THE  CEILING  FRAME  IS  ADE-
QUATELY SUPPORTED TO SUPPORT THE WEIGHT OF THE 
HEATER,  OR  THAT  THE  HEATER  IS  INDIVIDUALLY  SUP-
PORTED.    THERE  IS  PROVISION  ON  THE  HEATER  FOR 
CHAIN OR WIRE, SUPPORT OR MOUNTING.

 

 

The weight of the HE7230/RX, HE7245/RX is 7kg 
The weight of the HE7260/RX is 10kg 

 
It is the sole responsibility of the installer to ensure 
that  the  points  of  attachment  to  the  building  are 
sound. Care must be taken to allow complete free 
air  movement  into  the  inlet  grilles  of  the  unit  to 
ensure  the  correct  working  operation  of  the 
heater. Carefully unpack the unit  and control box. 
The unit is supplied with a length of self-adhesive 
foam strip.  This can be cut into lengths and  is to 
be  laid  on  the  4  sides  of  the  ceiling  frame  .    This 
will  ensure  that  the  unit  assembly  is  free  from  vi-
bration.    The  discharge  grille  and  diffuser  assem-
bly can now be fitted into the ceiling frame. 

 

 
 
 
 
 
 
 
 

 
 
 

4.1  Electrical Connections.  
 

These  units  are  suitable  for  connection  to  a 
230/240 Volt 50 Hz single phase supply. 
 
The  appliance  shall  be  connected  to  the  supply 
via  an  appropriate  switched  fused  double  pole 
isolator  having  a  contact  separation  of  greater 
than  3mm. Test for correct operation  and refit the 
cover. 

 

3. Installation Details. 

Fig.1 Air discharge of HE7230/RX and HE7245/RX 

 

Fig.2 Air discharge of HE7260/RX

 

TOP OR SIDE CABLE ENTRY 
 
TERMINAL COVER 

For  connection  to  the  mains  supply  it  will  be    
necessary to open  the terminal cover at the side/
back  of  the  unit  to  connect  the  supply  from  the 
controls  prior  to  refitting  the  cover. Wire  in  accor-
dance to the wiring diagrams. 
 
For  safety  reasons,  a  sound  earth  connection 
must always be made to the unit before it is put to 
use.  The  unit  should  be  wired  in  accordance  with 
IEE  Regulations  for  the  Electrical  Equipment  of 
Buildings.

 

 

4. Electrical Connections. 

41001456 Iss 01 

Fig.3 Mounting supports

 

The wire or chain used to mount the heater can be 
attached  to  4  of  the  M6  studs  or  the  4  x  M6 
threaded inserts as shown in diagram.

 

Содержание HE7230

Страница 1: ...01 RECESSED WARM CEILING HEATERS CATALOGUE NUMBERS HE7230 HE7245 HE7260 HE7230RX HE7245RX HE7260RX INSTALLATION AND OPERATING MANUAL Consort Equipment Products Limited Thornton Industrial Estate Milford Haven Pembrokeshire SA73 2RT Tel 01646 692172 Fax 01646 695195 Mon to Fri 8 30 am to 3 30 pm Email enquiries consortepl com Web www consortepl com ...

Страница 2: ... the installer should ensure that a suitable isolating switch is connected in the mains supply 1 4 Controller RX models The HE7230RX HE7245RX HE7260RX heaters are supplied without a controller The RX models will not work without the controller See section 5 1 for more details 1 5 Controller standard models The HE7230 HE7245 HE7260 heaters are sup plied with a remote controller The remote control u...

Страница 3: ...ation Sole liability rests with the installer to ensure that protective safety wear such as hand eye ear and head protection is used during installation of the product 1 General Information Do not rest anything especially ladders against the product 1 10 Standards Units conform to the European electrical standard BS EN 60335 2 30 2 Dimensions 41001456 Iss 01 ...

Страница 4: ...s free from vi bration The discharge grille and diffuser assem bly can now be fitted into the ceiling frame 4 1 Electrical Connections These units are suitable for connection to a 230 240 Volt 50 Hz single phase supply The appliance shall be connected to the supply via an appropriate switched fused double pole isolator having a contact separation of greater than 3mm Test for correct operation and ...

Страница 5: ...switch supplied eg BMS then the heat output can be selected by connecting the appropriate terminals WIRED TERMINALS HE7230 HE7245 HE7260 H1 H2 F 3000W 4500W 6000W H1 F 1000W 1500W 2000W H2 F 2000W 3000W 4000W Please note the F terminal must always be connected F Fan H1 Heating element 1 H2 Heating element N Neutral E Earth 41001456 Iss 01 Fig 5 Remote switch terminal side view Fig 4 Mains supply d...

Страница 6: ...The thermostat should be wired between the isolator switch and the heater remote switch For HE7245 HE7260 or to control more than one HE7230 heaters by a thermostat a contactor or a relay in conjunction with the thermostat should be used 5 Operation 4 Electrical Connections 4 4 Electrical connections for wireless control models Fig 8 Heater with terminal cover open Fig 9 Terminal cover detail To s...

Страница 7: ...Thermal cut out The units are protected from overheating in the event of fan failure or an obstruction of the free airflow by thermal cut outs If this happens the thermal cut outs switch off the appliance The ap pliance will not operate until the heater is discon nected from the mains supply and it has cooled down If this fault re occurs again refer to the section 6 4 fault finding 6 Servicing Mai...

Страница 8: ...8 ...

Отзывы: