CHMC Controller
The heater has to be configured for a se-
lected control method at the time of instal-
lation. To control the heater using a CHMC
controller the DIP switch 1 located under the
electrical connections cover has to be set
to
‘0’
as on the picture.
4.6
Connecting heaters to the CHMC
The CHMC is connected to the heater by
CAT5/CAT6 RJ45 cable. The RJ45 connector
is located under the terminals cover on the
bottom of the heater. There are 2 equal
RJ45 connectors in each heater. The con-
troller can be connected to any one. The
second connector is used If there are addi-
tional heaters in the system for a daisy
chain connection. Controller is powered via
the RJ45 connector.
Each heater in the sys-
tem must be set to unique ID. This is se-
lectable by DIP switches 2,3 and 4.
4. Selecting heater controls
5. Dimensions & Fixing locations