background image

10

 

 

51000486 Iss 01

 

 

7.2 General Data

 

 

 

CH06CSi

 

 

 

 

Installation height

 

M

 

2.4  

-

  4

 

 

M

 

 

 

 

Heat medium

 

 

 

Electric heating element

 

Heat output

 

kW

 

6

 

 

 

Fan type 

 

 

 

EC centrifugal fan 133

-

190

 

Fan control

 

 

 

Electronic  fan speed control 

 

Switching type

 

 

 

Solid state electronic control

 

Weight

 

kg

 

10

 

 

 

Electrical Data

 

Supply voltage

 

 

 

240V ~ 50Hz single phase only

 

Total load 

 

 

kW

 

26

 

 

 

Max current 

 

 

A/pha

 

 

 

 

Max motor power

 

 

W

 

120

 

 

 

External fuse size amps

 

A/pha

 

32

 

 

 

Controller

 

 

CRXSL wireless or CHMC Touch screen controller

 

Controller wiring

 

 

 

CAT5 / CAT6 with RJ45 connectors

 

Cable terminal size

  

 

10mm ²Max 

 

 

 

Mains terminal block position

 

 

 

Bottom of the heater. 

 

Terminals N; L

 

 

Control terminal position

 

 

 

Bottom of the heater. 

 

Air Data

 

Air volume 

 

 

Max speed

 

m³/h

 

900

 

 

 

Air velocity 

 

 

 

 

 

 

 

 

Max speed  @ 0M

 

m/s

 

9.5

 

 

Noise level @ 3m 

 

Max speed

 

dBA

 

60

 

 

Min speed

 

dBA

 

50

 

Dims Data

 

Width

 

mm

 

 

  332

 

 

Depth

 

mm

 

338

 

Height

 

mm

 

272

 

 

 

 

 

 

 

 

 

7. Technical Specifications

 

Содержание CH06CPiRX

Страница 1: ...any person not authorised by us This guarantee is offered to you as an extra benefit and does not affect your legal rights The correct electricity supply voltage is shown on the rating label attached...

Страница 2: ...he CRXSL wireless controller 4 5 CHMC controller 4 6 Connecting heaters to the CHMC controller 5 Dimensions and fixing location 6 Installation details 6 1 Mounting 6 2 Electrical connections 7 Technic...

Страница 3: ...ng points are suitable for the weight of the appliance 1 3 Electrical Supply This heater must be permanently con nected to the electricity supply via a double or 4 pole switch having 3mm gap on each p...

Страница 4: ...ons re mote temperature measuring microwave occupancy sensor and remote or boost switch connection All functions are fully pro grammable and can be associated with any heaters in the system The contro...

Страница 5: ...d depend ing on which heat mode is activated it will calculate the best possible airflow and adjusts the fan speed accordingly In order to maintain a constant airflow temperature the fan runs at a low...

Страница 6: ...eater controls 4 3 Heater status indication 4 4 Operation of CRXSL The CRXSL controller will come factory set in temperature control mode This can be changed to manual operation mode which simulates a...

Страница 7: ...the heater by CAT5 CAT6 RJ45 cable The RJ45 connector is located under the terminals cover on the bottom of the heater There are 2 equal RJ45 connectors in each heater The con troller can be connecte...

Страница 8: ...the heater to the wall bracket Finally adjust the direction of the heater to the desired area and tighten up all clamp ing nuts and bolts Care should be taken when choosing a posi tion ideally there s...

Страница 9: ...urrent per phase A pha 8 5 13 16 5 Max motor power W 120 120 120 External fuse size amps A pha 16 16 20 Controller CRXSL wireless or CHMC Touch screen controller Controller wiring CAT5 CAT6 with RJ45...

Страница 10: ...load kW 26 Max current A pha Max motor power W 120 External fuse size amps A pha 32 Controller CRXSL wireless or CHMC Touch screen controller Controller wiring CAT5 CAT6 with RJ45 connectors Cable ter...

Страница 11: ...11 51000486 Iss 01 8 Wiring Details 8 1 Installer Wiring 3 phase heaters CAT5 cable...

Страница 12: ...12 51000486 Iss 01 8 Wiring Details 8 2 Installer Wiring single phase heaters CAT5 cable...

Страница 13: ...13 51000486 Iss 01 8 3 Factory Wiring 3 phase heaters temperature sensor...

Страница 14: ...14 51000486 Iss 01 8 4 Factory Wiring single phase heaters temperature sensor...

Страница 15: ...LEDs on the RJ45 connect ors indicating that the power is available If the heater is in stand by mode the green LED is ON If the heater is switched ON the orange LED is indicating that the auxil iary...

Страница 16: ...onfigura tion All possible addresses RS485 serial half duplex interface MODBUS RTU 9600 baud 8 bits 1 start bit no parity 2 stop bits mark parity 1 stop bit Supported MODBUS function codes 0x03 read m...

Страница 17: ...gn for Energy Related Products and Energy Information Amendment EU Exit Regulations 2019 SI 2010 2617 The Restriction of use of Certain Hazardous Substances SI 2012 No 3032 Transposed standards used B...

Страница 18: ...18 51000486 Iss 01...

Отзывы: