background image

Printed in U.S.A.

©2014 Central Boiler

(p/n 9000166 REV. A) - 27-Jan-14

1-YEAR LIMITED WARRANTY

Central Boiler, Inc. ("Central Boiler") warrants to the original owner, except (a) parts manufactured by others and 

excluded from warranty coverage below; and (b) parts or items specified below, Central Boiler Classic and E-Classic 

furnaces against defects in workmanship for a period of ONE (1) YEAR from the date of original retail purchase.

An optional 25-Year Warranty is available if a Limited Warranty Registration 

Form is completed and sent to Central Boiler within five (5) days of the original 

owner taking possession of the furnace AND provided that one thermostatic 

valve per set of supply and return lines is installed in the system.

If a defect exists, at its option Central Boiler will (1) repair the defective part at no charge, using new or refurbished 

replacement parts, (2) exchange the furnace with a comparable model furnace that is new or which has been manufactured 

from new or serviceable used parts and is at least functionally equivalent to the original furnace, or (3) refund the 

purchase price. A replacement furnace/part assumes the remaining warranty of the original furnace/part or ninety (90) 

days from the date of replacement or repair, whichever provides longer coverage for you. If a furnace or part is qualified 

for replacement under the provisions of this limited warranty, at Central Boiler's discretion, the furnace or part may be 

required to be returned to Central Boiler for inspection and recycling or disposal.
This Limited Warranty applies only to Central Boiler Classic and E-Classic outdoor furnaces. This limited warranty 

covers only those defects that arise as a result of normal use of the outdoor furnace and does not cover any other defects 

or problems, including those that arise as a result of: (a) improper maintenance (b) operation outside the furnace's 

specifications, accident, abuse, misuse, misapplication, or parts that are not factory-installed; (c) service performed by 

anyone other than Central Boiler unless authorized by Central Boiler in writing; (d) modifications undertaken without 

the written permission of Central Boiler; or (e) if any Central Boiler serial number has been removed or defaced. This 

warranty excludes the cost of shipping, labor to remove or reinstall the furnace, plumbing labor and/or parts and the cost 

of alternative heat if the furnace is out of service for repairs. Warranty excludes replacement of water, inhibitors or other 

additives.
The following parts are not covered by this limited warranty: Warranty excludes gaskets, seals, heat shields, paint, charge 

tube, grates, combustors, aquastats, actuators, heat refractory, firebrick, chimney sections, and chimney tee, parts used in 

the system whether or not mounted on the furnace, such as pumps, valves, and piping.  
Parts that are factory-installed by Central Boiler, but are manufactured by others, may be covered by their own 

manufacturer's warranty and are not covered by this limited warranty. 
Central Boiler is not liable for damage or repairs required as a consequence of faulty installations or applications by 

others or any event of force majeure. Central Boiler is not liable for incidents or accidents which can be prevented by the 

owner or that occur from the operation of the outdoor furnace. A backup heating system should be in place to prevent 

damage in case of failure to refuel the outdoor furnace or mechanical failure of the outdoor furnace or system occurs. 

Heat replacement representations found in Central Boiler promotional information should be used only as a guideline. 

Heat loss for all applications with all weather extremes and other heat variables must be considered when sizing an 

outdoor furnace for different applications.
THIS WARRANTY AND REMEDIES SET FORTH ABOVE ARE EXCLUSIVE AND IN LIEU OF ALL OTHER 

WARRANTIES, REMEDIES AND CONDITIONS, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED. 

CENTRAL BOILER SPECIFICALLY DISCLAIMS ANY AND ALL IMPLIED WARRANTIES, INCLUDING, 

WITHOUT LIMITATION, WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR 

PURPOSE. IF CENTRAL BOILER CANNOT LAWFULLY DISCLAIM IMPLIED WARRANTIES UNDER THIS 

LIMITED WARRANTY, ALL SUCH WARRANTIES, INCLUDING WARRANTIES OF MERCHANTABILITY 

AND FITNESS FOR A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO THE DURATION OF THIS 

WARRANTY. No Central Boiler dealer or employee is authorized to make any modification, extension, or addition 

to this warranty. CENTRAL BOILER IS NOT RESPONSIBLE FOR DIRECT, SPECIAL, INCIDENTAL OR 

CONSEQUENTIAL DAMAGES RESULTING FROM ANY BREACH OF WARRANTY OR CONDITION, OR 

UNDER ANY OTHER LEGAL THEORY. Some states and provinces do not allow the exclusion or limitation of 

incidental or consequential damages or exclusions or limitations on the duration of implied warranties or conditions, so 

the above limitations or exclusions may not apply to you. This warranty gives you specific legal rights, and you may also 

have other rights that vary by state or province.

Содержание CL 4030

Страница 1: ...ur authorized Central Boiler dealer or heating contractor Record the information below for future reference Model Serial Number Installation Date Dealership Name Phone Number Owner Name CL 4030 CL 503...

Страница 2: ...d listed French Owner s Manual and decal set available upon request from your dealer Manuel d installation en fran ais et d calcomanies disponible sur demande aupr s de votre revendeur Manuel d instal...

Страница 3: ...Water Heat Transfer System 24 Vented System Installation 25 Direct Circulation Baseboard Installation 26 Radiant Floor System Installations 27 Pool and or Hot Tub Heating 30 FINALIZING THE INSTALLATIO...

Страница 4: ...Troubleshooting Section 6 General Information Anyone owning or operating this outdoor furnace must read fully understand and follow all of the information in this manual NOTE In higher populated area...

Страница 5: ...component WARNING Allow the outdoor furnace to thoroughly cool and completely clean out the firebox before draining water from the outdoor furnace If the water in the outdoor furnace ever boils be su...

Страница 6: ...NOTE Do not use chemicals or fluids to start the fire Use kindling and a small amount of paper to start an initial fire NOTE This outdoor furnace is not to be used with an automatic stoker WARNING Wh...

Страница 7: ...see Fig 4 INSTALLATIONS IN MASSACHUSETTS 1 All installation components must be products approved in the Commonwealth of Massachusetts by the Gas and Plumbing Board 2 The maximum run of tubing from th...

Страница 8: ...of a foundation If the ground is unstable one option is to use patio blocks under the perimeter of the base Another option is to pour a concrete foundation To install the furnace on a concrete founda...

Страница 9: ...imperative to add Central Boiler Corrosion Inhibitor Plus p n 1650 For recommended initial treatment rates refer to Water Quality and Maintenance When initially filling the system see Finalizing the...

Страница 10: ...recommends using ThermoPEX Be sure that both the insulation and the supply and return lines will not be exposed to ultraviolet rays The ThermoPEX black exterior jacket has UV protection but the insula...

Страница 11: ...the proper operation of the outdoor furnace Installing a swing check valve in the return line can prevent possible reverse flow Water Flow For a single building water to air heat exchanger system with...

Страница 12: ...12 Section 1 Furnace Installation 1 Pump Configuration Taco 007 Fig 9 3 Pump Configuration Taco 007 Fig 10 1 Pump and 3 Pump Parts List Taco 007 Fig 11...

Страница 13: ...alled in a horizontal position B The junction box must not be located below the pump motor see Fig 14 If necessary remove the four screws and rotate the pump body Fig 14 C Do not operate the circulati...

Страница 14: ...ot water boils at a lower temperature when pulled uphill because it is at a lower pressure therefore hot water must be pushed uphill to ensure proper circulation Fig 17 If water is to be pumped uphill...

Страница 15: ...erating the outdoor furnace with the water temperature less than 150 F 65 C may result in more condensation in the firebox that can lead to corrosion NOTE The thermostatic valve must be installed in t...

Страница 16: ...16 Section 1 Furnace Installation...

Страница 17: ...ater heat exchanger the hot supply line from the outdoor furnace should be plumbed first to the water heater heat exchanger and then to the balance of the heating system A manual 3 way valve may be in...

Страница 18: ...exchanger it should be mounted in the center without gaps on the sides that would allow air to flow around the heat exchanger All air must be directed through the face of the exchanger Air flow defle...

Страница 19: ...19 Section 1 Furnace Installation Fig 24...

Страница 20: ...20 Section 1 Furnace Installation Fig 25...

Страница 21: ...rate if the outdoor furnace is out of fuel Refer to Fig 26 for one possible arrangement 2 An alternative method is to install a line voltage thermostat to control the blower on the forced air furnace...

Страница 22: ...on multiple zones if one pump fails Hose bibs p n 199 should be installed on each supply and return manifold as illustrated in Fig 27 to allow for purging air from the zones Models with side panels of...

Страница 23: ...ter temperature of approximately 165 F Some existing finned tube baseboard hot water heating systems are designed to operate with water temperatures up to 220 F or higher If the existing heating syste...

Страница 24: ...165 F of water temperature transfer The temperature controller on the outdoor furnace may be adjusted to allow the outdoor furnace to reach water temperatures up to 195 F Each system will vary in wate...

Страница 25: ...return line s A flow check or zone valve will prevent thermal circulation and overheating of building It is very important to eliminate all air and water leaks valve packings bleeders etc and purge al...

Страница 26: ...er applications are easily plumbed into the water lines from the outdoor furnace Fig 31 and 32 illustrate direct circulation baseboard installation examples Fig 31 Return to Outdoor Furnace This horiz...

Страница 27: ...ig 36 The spacing of each circuit should be 12 between tubes The water circulates in opposite directions to provide an even distribution of heat The mixing valve regulates the temperature of the water...

Страница 28: ...28 Section 1 Furnace Installation Fig 34 Fig 35...

Страница 29: ...29 Section 1 Furnace Installation Fig 36 Fig 37...

Страница 30: ...e the Hydronic Component Selection Guide p n 2482 for more information CAUTION Do not install a swimming pool heat exchanger inside a home or building below the level of the pool as a damaged heat exc...

Страница 31: ...he area where the supply and return lines enter the outdoor furnace Do not leave the PEX hot supply and return lines exposed to sunlight as exposure to UV rays will damage them 5 Add Corrosion Inhibit...

Страница 32: ...ter as it heats up 9 Close the two filling valves 10 Open all valves on the outdoor furnace and turn on the circulation pump s This will allow the water to circulate throughout the outdoor furnace sys...

Страница 33: ...od contains about 50 moisture by weight Energy is required to heat the wood and evaporate the moisture energy which could have been used to provide heat for the home The illustration below shows that...

Страница 34: ...iodically during the normal operation of the outdoor furnace look at the water temperature display It should indicate a reading that is within 10 F of the controller setting Areading of 212 F or above...

Страница 35: ...p on the firebox walls flue and chimney If present the buildup should be removed for proper operation and fire safety Creosote if ignited in the chimney results in an extremely hot chimney fire In cas...

Страница 36: ...actors including your heat load requirements type of wood used and outdoor temperatures NOTE Proper firebox maintenance is essential to the longevity of the outdoor furnace CAUTION Do not burn plastic...

Страница 37: ...ible container 3 5 Firebox Door Seal The firebox door rope must be in good condition to ensure an airtight seal Look for wear spots or portions of the door rope lacking an indentation from the firebox...

Страница 38: ...at is too high the results should be verified using a new test kit The pH test strips and Permanganate Reagent each have a varying shelf life that can affect their accuracy Test kits should be stored...

Страница 39: ...st Kit p n 405 If antifreeze has been added to the water use Test Kit p n 597 3 Dip the pH test strip from the test kit in the water sample Shake excess water off the test strip Compare the color of t...

Страница 40: ...erioration If any corrosion or deterioration is found call your dealer It is always better to do maintenance during the non heating season 4 After the inspection is completed apply a thin coat of new...

Страница 41: ...l rope and clean any remaining silicone adhesive from the groove Any residue left in the groove will interfere with the new seal 4 Apply a 1 4 6 mm diameter bead of silicone sealant into the entire fi...

Страница 42: ...e cover then remove the cover CAUTION Solenoid may be hot 2 Carefully disconnect the two wire leads connected to the left side of the solenoid by gently pulling and moving them from side to side 3 Rem...

Страница 43: ...Temperature Sensor If the sensor needs to be replaced see Replacing Water Temperature Sensor TESTING WATER TEMPERATURE SENSOR 1 Disconnect the electrical power at the main power source to the outdoor...

Страница 44: ...imney tee 8 Building s poorly insulated or uninsulated Poorly insulated or uninsulated buildings buildings with uninsulated or poorly insulated ceilings or a lack of proper insulation under radiant fl...

Страница 45: ...be drained and then cleaned using Sludge Conditioner p n 166 The system must then be refilled with the proper amount of Corrosion Inhibitor Plus p n 1650 and fresh water 3 Water will not circulate If...

Страница 46: ...46 Section 6 General Information SECTION 6 GENERAL INFORMATION Make note of these precautionary statements also found on the furnace...

Страница 47: ...4706 6146 5032 812 75 846 4279 880 Sight Gauge 4278 3 4283 3 891 727 1085 Fuse Holder 4501 Fuse 7632 6500002 2 6751 10882 10854 011 4283 2 10792 10853 011 6725 10792 4283 2 852 3033 6649 6510 4626 66...

Страница 48: ...e 4278 3 4283 3 7632 6500002 2 6751 10854 011 4283 2 10792 10853 011 6725 10792 4283 2 2000155 11998 6508 3667 6501 6650 6514 4707 Door Rope 3033 4626 2013 Central Boiler 1085 Fuse Holder 4501 Fuse 65...

Страница 49: ...10529 4 5924 2 5062 2 5064 2 852 2 4630 2 6649 6509 6510 6146 5032 812 75 846 4279 880 Sight Gauge 4278 3 4283 3 7632 6751 6725 10853 011 10854 011 4283 2 6500002 2 10792 3033 10792 4283 2 4708 Door...

Страница 50: ...50 Section 6 General Information FURNACE MEASUREMENTS...

Страница 51: ...51 Section 6 General Information WIRING DIAGRAMS Fig 51...

Страница 52: ...out of service for repairs Warranty excludes replacement of water inhibitors or other additives The following parts are not covered by this limited warranty Warranty excludes gaskets seals heat shield...