![CLAS OH 7014 Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/clas/oh-7014/oh-7014_manual_2616368017.webp)
OH 7014
EXTRA FLAT TROLLEY JACK 3T 75mm
SYSTEM AIR PURGE PROCEDURE
IMPORTANT: BEFORE FIRST USE
Perform the following Air Purge Procedure to remove any air that may have been introduced into
the hydraulic system as a result of product shipment and handling. This step is to be completed
without any weight on the jack.
t
1
Remove cover plate.
2
Turn release valve counter-clockwise
on full turn to the open position.
Rapidly pump the handle 6-8 times.
Leave handle in down position to
expose oil fill plug.
3
With a flat blade screwdriver, push the
oil fill plug slightly to the side to purge
trapped air from system. (Use caution
not to tear or puncture the oil plug.)
4
Replace Cover Plate.
5
7
Cover plate
Cover plate
Turn release valve clockwise to the
closed position.
6
Jack is now ready for use. Check for
proper pump action. (Repeat steps if
neccessary).