1.  Shiny or polished surfaces can give inaccurate readings. To compensate for lhis, caver the 

surface with masking tape or fi at colored paint. When the tape or paint reaches the same 

temperature as the target underneath, measure the tempe rature of the item. 
2. The thermometer cannai measure through transparent surfaces such as glass or plastic. Il 

will measure the surface temperature instead.
3.  Steam, dust, smoke, and other optical obstructions can prevent accurate measurement.

The farther the thermometer is from the target, the larger the target area will be. This 

relationship between distance and target size is normally expressed as the distance to 

spot, or D: S ratio. Al a distance of 16cm, the «target» spot would be 2cm in diameter. The 

thermometer will display the average temperature across the target area.

To clean the lens: Blow off  loose particles using clean compressed air. Gently brush remaining 

debris away with a moisi cotton cloth. 
To clean the case: Wipe the case with damp, soft cloth. 
Note: Do not use solvent or abrasive to clean the lens or the case, and do not submerge the 

thermometer under water

FIELD OF VIEW

MAINTENANCE

Distance

Distance to Spot size = 8:1

6cm@48cm

4cm@32cm

2cm@16cm

Spot 

center

Содержание OE 5036

Страница 1: ...clas com THERMOMETRE INFRAROUGE 38 520 OE 5036 INFRARED THERMOMETER 38 520...

Страница 2: ...ur notre site clas com Si vous avez chang d avis concernant votre achat veuillez retourner ce produit avant d essayer de l installer Before returning this product for any reason installation problem i...

Страница 3: ...laser vers les yeux d autrui et faire attention ne pas atteindre les yeux d autrui en dirigeant le faisceau laser sur une surface r fl chissante 4 Garder hors de port e des enfants 5 Ne pas utiliser l...

Страница 4: ...esur e et la temp rature de r f rence est comprise dans les limites du seuil d fini LOW Appara t lorsque la diff rence entre la temp rature mesur e et la temp rature de r f rence est inf rieure au seu...

Страница 5: ...couvercle vers le bas Remplacez les piles usag es par des piles neuves en faisant attention la polarit Remettez le couvercle 1 Pointez le thermom tre vers la cible Appuyez sur la g chette et maintenez...

Страница 6: ...que la diff rence entre la temp rature mesur e et la temp rature de r f rence est inf rieure au seuil d fini la lumi re de r tro clairage est bleue et le symbole LOW appara t en haut et droite de l cr...

Страница 7: ...sser les mesures Plus le thermom tre est loign de la cible plus le diam tre de la cible est large Ce rapport entre la distance de la cible et le diam tre du champs de mesure s exprime par D S Lorsque...

Страница 8: ...ondensation Conditions de stockage 20 C 60 C 85 humidit relative Dimensions 160 x 118 x 40 mm Poids 155g environ piles incluses 1 Des modifications peuvent tre apport es ce mode d emploi tout moment 2...

Страница 9: ...Use extreme caution when operating the laser 3 Do not point the laser beam toward anyone s eye or allow the laser beam to strike the eye from a reflective surface 4 Keep the thermometer out of reach...

Страница 10: ...ce between the presently scanned temperature and the reference temperature does not exceed the threshold LOW Appears when the presently scanned temperature is lower than the reference temperature by m...

Страница 11: ...t the polarity connections are correct Reinstall the battery caver 1 Hold the thermometer and point it toward the target to be measured Pull and hold the trigger for at least 1 second to start measuri...

Страница 12: ...nd slow beeps about one beep per second if the presently scanned tempe rature is lower than the reference temperature by more than the threshold The backlight will be red and the symbol HIGH will appe...

Страница 13: ...her the thermometer is from the target the larger the target area will be This relationship between distance and target size is normally expressed as the distance to spot or D S ratio Al a distance of...

Страница 14: ...condensing Storage Temperature 20 C 60 C 85 RH Dimensions 160 X 118 X 40mm Weight About 155g including battery 1 This Instruction Sheet is subject to change without notice 2 CLAS will not take the oth...

Страница 15: ......

Страница 16: ...revendeur En cas de probl me veuillez contacter le technicien de votre distributeur agr CLAS Equipements 83 chemin de la CROUZA 73800 CHIGNIN FRANCE T l 33 0 4 79 72 62 22 Fax 33 0 4 79 72 52 86 THERM...

Отзывы: