background image

 OE  5036 

 INFRARED THERMOMETER -38°/520° 

3. Battery Charge Level lndicator

lndicates that the batteries are high and measurements are possible.

lndicates that the batteries are low and should be replaced immediately although 

measurements are still possible.

lndicates that the batteries are exhausted. 

4. 

Scanned Temperature

5. 

Reference Temperature lndicator

6. 

Arrowhead lcons for lndicating the Threshold

7.  

Reference Temperature

8.  

Units

When the battery charge level indicator shows   the batteries are low and should be 

replaced immediately. 
Wait until the thermometer turns off  automatically, then remove the battery caver by moving 

it downwards. Replace the old batteries with new ones of the same type, make sure that the 

polarity connections are correct. Reinstall the battery caver.

1. Hold the thermometer and point it toward the target to be measured. Pull and hold the 

trigger for at least 1 second to start measuring. When the thermometer is in measurement 

state, the backlight and the laser are on, and the screen shows the icon «SCAN». When you 

release the trigger, the thermometer sounds 3 beeps and the laser turns off  and the last 

temperature reading is held on the screen. If you have not operated the thermometer for 

about 15 seconds, the backlight will turn off  automatically, and, If you have not operated the 

thermometer for about 1 minute, the thermometer will turn off  automatically. 

2. When the thermometer is in measurement state ( the trigger is pulled and held ), you can 
press the «

» Button to set the reference temperature, which is shown on the secondary 

display (the lower display).

INSTALLING BATTERY

OPERATING INSTRUCTIONS

Содержание OE 5036

Страница 1: ...clas com THERMOMETRE INFRAROUGE 38 520 OE 5036 INFRARED THERMOMETER 38 520...

Страница 2: ...ur notre site clas com Si vous avez chang d avis concernant votre achat veuillez retourner ce produit avant d essayer de l installer Before returning this product for any reason installation problem i...

Страница 3: ...laser vers les yeux d autrui et faire attention ne pas atteindre les yeux d autrui en dirigeant le faisceau laser sur une surface r fl chissante 4 Garder hors de port e des enfants 5 Ne pas utiliser l...

Страница 4: ...esur e et la temp rature de r f rence est comprise dans les limites du seuil d fini LOW Appara t lorsque la diff rence entre la temp rature mesur e et la temp rature de r f rence est inf rieure au seu...

Страница 5: ...couvercle vers le bas Remplacez les piles usag es par des piles neuves en faisant attention la polarit Remettez le couvercle 1 Pointez le thermom tre vers la cible Appuyez sur la g chette et maintenez...

Страница 6: ...que la diff rence entre la temp rature mesur e et la temp rature de r f rence est inf rieure au seuil d fini la lumi re de r tro clairage est bleue et le symbole LOW appara t en haut et droite de l cr...

Страница 7: ...sser les mesures Plus le thermom tre est loign de la cible plus le diam tre de la cible est large Ce rapport entre la distance de la cible et le diam tre du champs de mesure s exprime par D S Lorsque...

Страница 8: ...ondensation Conditions de stockage 20 C 60 C 85 humidit relative Dimensions 160 x 118 x 40 mm Poids 155g environ piles incluses 1 Des modifications peuvent tre apport es ce mode d emploi tout moment 2...

Страница 9: ...Use extreme caution when operating the laser 3 Do not point the laser beam toward anyone s eye or allow the laser beam to strike the eye from a reflective surface 4 Keep the thermometer out of reach...

Страница 10: ...ce between the presently scanned temperature and the reference temperature does not exceed the threshold LOW Appears when the presently scanned temperature is lower than the reference temperature by m...

Страница 11: ...t the polarity connections are correct Reinstall the battery caver 1 Hold the thermometer and point it toward the target to be measured Pull and hold the trigger for at least 1 second to start measuri...

Страница 12: ...nd slow beeps about one beep per second if the presently scanned tempe rature is lower than the reference temperature by more than the threshold The backlight will be red and the symbol HIGH will appe...

Страница 13: ...her the thermometer is from the target the larger the target area will be This relationship between distance and target size is normally expressed as the distance to spot or D S ratio Al a distance of...

Страница 14: ...condensing Storage Temperature 20 C 60 C 85 RH Dimensions 160 X 118 X 40mm Weight About 155g including battery 1 This Instruction Sheet is subject to change without notice 2 CLAS will not take the oth...