 DIGITAL MULTIMETER CAT. III 

Non-Contact AC Voltage Detection

Press and hold down the AC Voltage Detection Button, move the top of the meter close to the object to be tested. 

When the meter detects AC voltage, the built-in buzzer will sound and the AC Voltage  Detection lndicator will 

light.

Note:

1. To avoid electric shock, do not touch any naked conductor with hand or skin.

2. Because of the meter's detection limit, a line ( or conductor) under test may be live even if the buzzer does not 

sound and the AC Voltage Detection lndicater does not light.

3. Before use, verify the meter's operation by detecting a known AC voltage.

4. When you just press and hold down the AC Voltage Detection Button, the buzzer may sound one or two beeps 

and the AC Voltage Detection lndicater may light briefl y. lt is normal and doesn't matter.

5. Don't use the meter in an environment with intense electromagnetic fi eld.

Live AC Wire Detection

Connect the plug of a test lead to an input terminal of the meter, and connect the probe tip of this test lead to the 

line's conductor to be tested. Press and hold down the AC Voltage Detection Button. When the meter detects AC 

voltage, the built-in buzzer will sound and the AC Voltage Detection lndicator will light.

Note:

1. To avoid electric shock, do not touch any naked conductor with hand or skin.

2. Because of the meter's detection limit, a line (or conductor) under test may be live even if the buzzer does not 

sound and the AC Voltage Detection lndicator does not light.

3. Before use, verify the meter's operation by detecting a known live ac wire (or conductor).

4. When you just press and hold down the AC Voltage Detection Button, the buzzer may sound one or two beeps 

and the AC Voltage Detection lndicator may light briefl y. lt is normal and doesn't matter.

5. Don't use the meter in an environment with intense electromagnetic fi eld.

 

 

Содержание OE 3004

Страница 1: ...clas com MULTIMETRE DIGITAL CAT III DIGITAL MULTIMETER CAT III OE 3004...

Страница 2: ...ant de brancher le c ble d essai sous tension Lorsque vous d branchez les c bles d essai veuillez d abord d brancher le c ble d essai sous tension Retirez les c bles d essai du multim tre avant d ouvr...

Страница 3: ...ien d autres fonctions encore Cet outil de test est facile utiliser et tr s pratique Il peut par exemple s agir de mesures relev es sur les tableaux de distribution les disjoncteurs l installation lec...

Страница 4: ...ble d essai rouge pour les mesures de courant 200mA 10A 7 Borne COM Cette borne est la prise de courant du c ble d essai noir Elle sert galement de prise de courant pour la borne n gative du thermoco...

Страница 5: ...au format de mesure nombre de chiffres les moins significatifs TENSION CONTINUE Plage R solution Pr cision Indication de d passement de plage 200mV 100 V 0 5 5 Seul le chiffre 1 est affich l cran 2V...

Страница 6: ...Pr cision Indication de d passement de plage 20mA 10 A 1 3 5 Seul le chiffre 1 est affich l cran 200mA 100 A 1 8 5 10A 10mA 3 0 5 1 Protection contre la surtension Fusible action rapide 250mA 300V po...

Страница 7: ...a temp rature ambiante est stable 1 C Lorsque la temp rature ambiante varie de 5 C le degr de pr cision est effectif apr s 1 heure Plage R solution Courant d essai 1 5V La tension de fonctionnement de...

Страница 8: ...pr sents c t de ce bouton 4 Coupez l alimentation du circuit tester Puis d chargez tous les condensateurs haute tension 5 Coupez le chemin du circuit tester et branchez les c bles d essai en s rie su...

Страница 9: ...ne VmA C 2 Selon la tension nominale de la batterie tester r glez le s lecteur de plage sur la position BATT correspondante 3 Branchez les c bles d essai sur les deux bornes de la batterie tester 4 L...

Страница 10: ...tim tre en pr sence d un champ lectromagn tique intense D tection de c bles lectriques sous tension alternative Branchez la borne d un c ble d essai sur une borne d entr e du multim tre et connectez l...

Страница 11: ...rectes qui pourraient entra ner un ventuel risque d lectrocution ou de blessure corporelle veuillez remplacer la batterie d s que le voyant de batterie faible appara t Pour viter tout endommagement ou...

Страница 12: ...en you disconnect test leads disconnect the live test lead first Remove the test leads from the meter before you open the battery cover or the case Do not operate the meter with the battery caver or p...

Страница 13: ...detection and illumination functions are also provided lt features polarity indication data hold overage indication etc lt is easy to operate and is a very useful test tool for example stationary moto...

Страница 14: ...00mA 1OA measurements 7 COM terminal This terminal is a plug in connecter for the black test lead lt is also a plug in connecter for the negative plug of the thermocouple for temperature measurements...

Страница 15: ...ticant Digits DC VOLTAGE Range Resolution Accuracy Overage indication 200mV 100 V 0 5 5 Only figure 1 shown on the display 2V 1mV 0 8 5 20V 10mV 200V 100mV 300V 1V 1 0 5 1 Input lmpedance 10M Max Allo...

Страница 16: ...Range Resolution Accuracy Overage indication 20mA 10 A 1 3 5 Only figure 1 shown on the display 200mA 100 A 1 8 5 10A 10mA 3 0 5 1 Overload Protection 250mA 300V FAST Fuse for VmA C terminal inputs 10...

Страница 17: ...is stable to 1 C For ambient temperatures changes of 5 C rated accuracy applies after 1 hour Range Description Test current 1 5V The working voltage of the battery will be shown on the display so that...

Страница 18: ...ent with the AC DC button according to the marks beside this button 4 Turn off power to the circuit to be tested Then discharge all highvoltage capacitors 5 Break the circuit path to be tested then co...

Страница 19: ...lack test lead to the COM terminal and the red test lead to the VmA C terminal 2 According to the rated voltage of the battery to be tested set the range switch to the corresponding BATT range positio...

Страница 20: ...n t use the meter in an environment with intense electromagnetic field Live AC Wire Detection Connect the plug of a test lead to an input terminal of the meter and connect the probe tip of this test l...

Страница 21: ...which could lead to possible electric shock or personal injury replace the battery as soon as the low battery indicator appears To prevent damage or injury use only replacement fuses specified Before...

Страница 22: ......

Страница 23: ......

Страница 24: ...icien de votre distributeur agr If you need components or parts please contact the reseller In case of problems please contact your authorized technician CLAS Equipements ZA de la CROUZA 73800 CHIGNIN...

Отзывы: