9
EN
G
LI
SH
Connecting devices to the generator’s 230 V outlets
Note:
• Only devices labelled as operating on 230 V, 50 Hz must be connected to the generator. Do not use
the 230 V and 12 V outlets at the same time, i.e., do not run 230 V appliances whilst simultaneously charging
a 12 V battery.
• The generator’s rated running output wattage is 2600 W under continuous operation, and its maximum
intermittent or surge wattage (for short bursts of extra power for starting appliances such as refrigerators)
is 3000 W.
• The total running wattage of the electrical devices connected to the generator should not exceed 2600 W.
1. Make sure that all electrical devices are switched off before they are connected to the generator.
2. Set the AC on/off switch (17) to
ON
.
3. Switch on the connected electrical devices in order of their wattage requirement. Begin with the device that
requires the most power.
Note:
The AC on/off switch also acts as an overvoltage safety cut-off switch and trips if the load of the electrical
devices becomes too high. Reduce the load and allow the generator to rest for a while before loading it again.
12 V outlet
Note:
• The 12 V outlet is only intended for charging lead-acid batteries (car batteries).
• The charging current varies according to the engine speed and load. The maximum charging current is 8 A.
• Battery charging must be supervised and discontinued manually otherwise there is a risk of the battery fluid
boiling and damaging the battery. Whilst a battery is being charged it will emit an explosive oxyhydrogen gas
mixture. Batteries should be charged in well-ventilated areas, and well away from sources of ignition.
• For more efficient car battery charging, we recommend that a 230 V AC car battery charger is connected to
the 230 V AC outlet of the generator.
• Do not connect batteries with capacities lower than 60 Ah.
• The 12 V outlet is unregulated, i.e. the output voltage depends on the speed of the engine and the load on
the generator.
• The overvoltage safety cut-off (20) will trip if the load from the connected 12 V device becomes too
high. If this happens, disconnect the battery and investigate the cause. Press the reset button in to reset
the overvoltage safety cut-off protection. Allow the generator to rest for a few minutes before it is put under
load again.
1. Connect the supplied cable to the 12 V outlet socket. It can only be connected one way, so there is no risk
of reversed polarity.
2. Connect the clamps to the battery terminals.
Note:
Ensure that the red cable clamp is connected to the positive battery terminal and the black cable clamp
to the negative terminal.
Switching the generator off
1. Turn off all connected electrical devices and then unplug them from the generator.
2. Set the AC on/off switch (17) to
OFF
.
3. Let the engine run for a few minutes to stabilize the temperature of the generator.
4. Set the engine on/off switch to
0
OFF
.
5. Turn the fuel cut-off valve to
OFF
.
Care and maintenance
• The exterior of the generator should be cleaned using a damp cloth. Only use mild cleaning agents,
never solvents or corrosive chemicals.
• If the generator is not to be used for a long time, empty the fuel tank, start the generator and run it on the fuel
remaining in the carburettor until it runs out of fuel. This ensures that the fuel does not become aged during
storage. Petrol which has been left in the carburettor during prolonged storage can lead to starting problems.