Trouble
Possible Cause
Suggested Remedy
Fans does not start after
pairing process
A) Remote and receiver are
not paired successfully
B) Battery flat in remote
control
C) Loose wire connections or
plugs to fan/receiver
D) No power goes into the
fan
A) Re-pair the receiver and
remote
B) Replace the battery in
remote control
C) Check wire connections
and ensure plugs are
positively connected
D) Check RCD/Switch board
and wiring on premises
Fan keeps beeping, but will
not start.
Loose wire connections or
plugs to fan/receiver
Check wire connections and
ensure plugs are positively
connected
Fan wobbles.
A) Screws on down rod are
not tightened
B) Blades are not balanced
A) Retighten the screws on
down rod
B) Use the balancing kit to
balance the blades.
Fan makes clicking sound.
A) Coupling cover does
not sit securely on motor
housing
B) Rubber ring on coupling
cover is removed
A) Adjust coupling cover and
ensure it sits properly on the
motor housing
B) Check couple cover and
ensure there’s a rubber ring
on the top of the cover.
12
Model Number
Rated Voltage
Motor Consumption Rated Light Power
CFCLSU2WH
220-240Vac
Max. 45 W DC Motor N/A
CFCLSU2LWH
220-240Vac
Max. 45 W DC Motor 18 W LED
CFCLSU2WHABS
220-240Vac
Max. 45 W DC Motor N/A
CFCLSU2LWHABS
220-240Vac
Max. 45 W DC Motor 18 W LED