9
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
WHEN STARTING SUBSEQUENTLY, START THE MACHINE AS FOLLOWS:
1. At the beginning of the day, open the drain cock and allow any
condensate to drain completely, then close the drain cock.
2. To ease starting, ensure there is no pressure in the pump outlet manifold by
opening the Bleed Valve (See Fig.2 on page 8).
3. Connect the air hose to one of the outlets and the air tool and set the
pressure regulator to zero pressure (turned fully anticlockwise).
4. Start the engine in accordance with the instructions contained in the
engine service manual, then close the bleed valve and allow pressure to
build up.
5. When the Air Governor/Load Genie has operated and the compressor has
gone ‘off line’, slide the outlet valve outwards fully then adjust the pressure
regulator so that the desired pressure is registered on the gauge.
6. Check for air leaks at the tool and connectors, before proceeding.
OUTLET PRESSURE ADJUSTMENTS
PORTABLE COMPRESSORS
1. Pressure Adjusting Knob
2. Outlet Taps
3. Pressure Gauge
TO ADJUST OUTLET PRESSURE:
To increase pressure - turn knob (1)
clockwise. To decrease pressure - turn
knob (1) anticlockwise.
Illustrative
purposes
only
FIG. 3