background image

9

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

WHEN STARTING SUBSEQUENTLY, START THE MACHINE AS FOLLOWS:

1. At the beginning of the day, open the drain cock and allow any 

condensate to drain completely, then close the drain cock.

2. To ease starting, ensure there is no pressure in the pump outlet manifold by 

opening the Bleed Valve (See Fig.2 on page 8). 

3. Connect the air hose to one of the outlets and the air tool and set the 

pressure regulator to zero pressure (turned fully anticlockwise).

4. Start the engine in accordance with the instructions contained in the 

engine service manual, then close the bleed valve and allow pressure to 
build up. 

5. When the Air Governor/Load Genie has operated and the compressor has 

gone ‘off line’, slide the outlet valve outwards fully then adjust the pressure 
regulator so that the desired pressure is registered on the gauge.

6. Check for air leaks at the tool and connectors, before proceeding.

OUTLET PRESSURE ADJUSTMENTS

PORTABLE COMPRESSORS

1. Pressure Adjusting Knob

2. Outlet Taps

3. Pressure Gauge

TO ADJUST OUTLET PRESSURE:

To increase pressure - turn knob (1) 
clockwise. To decrease pressure - turn 
knob (1) anticlockwise.

Illustrative
purposes
only

FIG. 3

Содержание XPP15/50

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0118 ISS 1 ORIGINAL INSTRUCTIONS 50L ENGINE DRIVEN AIR COMPRESSOR MODEL NO XPPV11 XPP15 RANGE...

Страница 2: ...VERED SPARE PARTS AND DIAGRAMS Spare parts and diagrams are available on request by contacting our parts and service department on 020 8988 7400 GUARANTEE This product is guaranteed against faulty man...

Страница 3: ...ines produce noise levels in excess of 70dB A Persons working in the vicinity of the machine must be provided with suitable ear protection XPPV11 50 XPPVH11 50 XPP15 50 XPPH15 50 Part Number 2092551 2...

Страница 4: ...d by load noise consult paint manufacturers instructions for safety and usage before spraying ensure that the air supply is turned off at the machine outlet and all pressurised air from the machine an...

Страница 5: ...r compressor with any guards removed FIRE PREVENTION ALWAYS switch the engine OFF when refuelling refuel away from any source of heat refuel in a well ventilated area DO NOT overfill the tank fill to...

Страница 6: ...settings these settings are set at the factory Should they need re calibration consult your Clarke dealer RESIDUAL RISK Although this manual contains extensive safety warnings and information on the s...

Страница 7: ...within the engine manual Ensure the fuel tap is set to the required position Ensure The fuel hose and connectors are intact in perfectly serviceable condition and there is no leakage NOTE Always use...

Страница 8: ...to allow air to escape from the outlets and slowly turn the pressure regulator clockwise Observe the pressure gauge When the pressure has dropped by approx 20psi the Air Governor Load genie will opera...

Страница 9: ...rned fully anticlockwise 4 Start the engine in accordance with the instructions contained in the engine service manual then close the bleed valve and allow pressure to build up 5 When the Air Governor...

Страница 10: ...se the air outlet by sliding both valves inwards 3 Operate the air tool trigger or operating lever etc to ensure there is no pressure in the air line then disconnect airline and tool 4 Finally close t...

Страница 11: ...nt If badly contaminated replace Remove any loose contaminants if any then replace 2 Clean the engine cooling fins 6 MONTHLY 1 Renew pump lubricating oil 2 Drain pump by removing the drain plug 3 Repl...

Страница 12: ...until the fault has been rectified SYMPTOM PROBABLE CAUSE REMEDY Engine difficult to start Load Genie leaking compressor unit is on load during start Stop engine and empty air receiver Clean or repla...

Страница 13: ...arke Service Department Inspection cover or drain plug leaking Empty air receiver and change seals plugs Pressure gauge defective Change pressure gauge Unit too small in relation to air consumption Us...

Страница 14: ...ervice Department Dirt on cooling fins or suction filter Clean cooling fins and suction filter Unit working at too high a pressure Contact Clarke Service Department Not fully unloading Contact Clarke...

Страница 15: ...compressor Cylinder worn Contact Clarke Service Department Intake air filter blocked Clean or replace Oil in the air delivered Sump over full Reduce oil to correct level Cylinder worn Contact Clarke S...

Страница 16: ......

Отзывы: