- 8 -
particles, which, if not cleaned away, will affect
the performance of the machine.
To clean the air intake filter, carefully prise out
the sponge element shown in fig.2. Clean the
sponge and the housing using a brush or clean
lint free cloth.
If necessary, the sponge filter may be gently
washed in warm soapy water, rinsed and
allowed to dry thoroughly before refitting.
Every 500 hours of operation or every 6 months
•
Clean all the external parts of the compressor.
(This cleaning makes the cooling process more efficient and prolongs the
life of the machine).
•
Examine the non-return valve and renew
if necessary (fig. 3)
(Ref: H Fig. 1, Item 18 page 15, and Item
10, page 16,)
•
In the event of an air leak follow the procedure below:
• Load compressor to maximum pressure
• Unplug the compressor
• With a brush and soapy water wet all ‘screwed’ air connections
• Any leaks will show through the formation of air bubbles.
•
Replace the piston (See your Clarke dealer)
WARNING
NEVER UNSCREW A CONNECTION WHILST THE AIR RECEIVER IS UNDER PRESSURE.
ALWAYS MAKE CERTAIN THAT THE TANK HAS FIRST BEEN EMPTIED.
Fig. 2
Fig. 3
- 13 -
PARTS DIAGRAM - PUMP
SPYDER 3 AND SPYDER 7