ELECTRICAL CONNECTIONS

Connect the mains lead to a standard, 230 Volt (50Hz) electrical supply
through an approved 13 amp BS 1363 plug, or a suitably fused isolator switch.

WARNING! THIS APPLIANCE MUST BE EARTHED

IMPORTANT:

 The wires in the mains lead are coloured in accordance

with the following code:

Green & Yellow

-

Earth

Blue

-

Neutral

Brown

-

Live

As the colours of the flexible lead of this appliance may not correspond
with the coloured markings identifying terminals in your plug proceed as
follows:

Connect GREEN & YELLOW cord to terminal marked with a letter “E”
or  Earth symbol “    ” or coloured GREEN or GREEN & YELLOW.

Connect BROWN cord to terminal marked with a letter “L” or
coloured RED.

Connect BLUE cord to terminal marked with a letter “N” or coloured
BLACK.

If this appliance is fitted with a plug which is moulded onto the electric
cable (i.e. non-rewireable) please note:

1.

The plug must be thrown away if it is cut from the electric cable.
There is a danger of electric shock if it is subsequently inserted into a
socket outlet.

2.

Never use the plug without the fuse cover fitted.

3.

When replacing a detachable fuse carrier, ensure the correct
replacement is used (as indicated by marking or colour code).

4.

Replacement fuse covers can be obtained from your local dealer
or most electrical stockists.

FUSE RATING

The fuse in the plug must be replaced with one of the same rating

 (13

amps)

 and this replacement must be ASTA approved to BS1362.

We strongly recommend that this machine is connected to the mains
supply via a Residual Current Device (RCD)

If in any doubt, consult a qualified electrician. DO NOT attempt any
repairs yourself.

- 5 -

PARTS DIAGRAM - RECEIVER AND COMPONENTS

A. SPYDER 7

- 16 -

Содержание SPYDER 3

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS SPYDER 3 7 OIL FREE AIR COMPRESSOR 0503 Serial Batch No SPYDER 3 7 OIL FREE AIR COMPRESSOR...

Страница 2: ...Supply 230 V 1 Phase 50Hz Motor Rating 1 5 HP Max Air Pressure 8 bar 116 lbf in2 Air Displacement 6 3 cuft min Air Receiver Spyder 3 2 litre Spyder 7 6 litre Nett Weight Spyder 3 10 5kg Spyder 7 14kg...

Страница 3: ...ives accurate control of the gun and material The distance between gun and surface should be 6 to 12 inches depending on material and atomizing pressure The material deposited should always be even an...

Страница 4: ...rial ALWAYS ensure that the air supply is turned off at the machine outlet and expel all pressurised air from within the machine and other equipment attached to it BEFORE disconnecting air hoses or ot...

Страница 5: ...oloured BLACK If this appliance is fitted with a plug which is moulded onto the electric cable i e non rewireable please note 1 The plug must be thrown away if it is cut from the electric cable There...

Страница 6: ...e not to over tighten If a rubber seal is damaged then it should be replaced If you do not wish to use the Quick Fit method of hose connection simply remove the Quick Fit nut and use an air hose fitte...

Страница 7: ...ero by turning the regulator knob fully anticlockwise 7 ROUTINE MAINTENANCE IMPORTANT Before carrying out any maintenance always disconnect the machine from the mains supply drain the air receiver and...

Страница 8: ...his cleaning makes the cooling process more efficient and prolongs the life of the machine Examine the non return valve and renew if necessary fig 3 Ref H Fig 1 Item 18 page 15 and Item 10 page 16 In...

Страница 9: ...116HP0002 3 Crank 1 FN116HP0003 4 Bearing 1 FN033047000 5 Rotor 1 FN034139000 6 Stator 1 FN316HP1604 7 Bearing 1 FN033005000 8 Housing 1 FN116120007 9 Bearing 3 FN014002124 10 Bolt M5 3 FN014003003 11...

Страница 10: ...g on Overload cutout switch has tripped The compressor stops and will not start again Bad connections Check electrical connections Clean and tighten as necessary The compressor does not reach the set...