SYMPTOM
PROBABLE CAUSES
REMEDY
Condensation at outlet
Piping installation incorrect.
Consult your local dealer.
points.
Compressor taking in air
Obtain better fresh-air
which is too warm.
supply for compressor.
Delivery temperature of air
a) Use a larger air receiver.
from air receiver too high.
b) Insert an aftercooler.
Electric Motor too hot:
Operational voltage too low.
Call an electrician.
maximum temperature Faults in electrical installation
Call an electrician.
90 C (194 F).
or electric motor.
Cooling fins of electric motor
Clean cooling fins.
blocked by dirt.
Machine running but
Air exhausting from solenoid
Check solenoid valve.
not pumping air into
after starter has changed from
Call an electrician to
receiver (10 HP and
star to delta.
check starter.
above).
OTHER PRODUCTS WITHIN OUR RANGEIn addition to Air Compressors from 3–80 cfm, we
offer a vast range of airtools and airline equipment. Please ask your local dealer for
details ofour range or a copy of our Power Products Catalogue
MAINTENANCE CHART
CHECK LIST
DAILY
WEEKLY
6 MONTHLY
Oil Level
Check
Change
Air receiver
Drain
Intake filter
Check/Clean
Replace if necessary
Oil breather
Check/Clean
Fan and Cooling
Clean
Fins
Inlet and Outlet
Check
Replace if worn
valves
Non-return valve
Clean
Replace if worn
Belt tension
Check/Adjust
Does not apply to
direct drive
Big end bearings
Check
Replace if worn
Main bearings
Check
Replace if worn
Piston rings
Check
Replace if worn
17