13
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
SPECIFICATIONS
ENVIRONMENTAL PROTECTION
These products contain valuable raw materials. Do not dispose of
this product with general household waste. All tools, accessories
and packaging should be sorted and disposed off appropriately
by taking to a recycling centre.
Heater shuts
down while
running
High surrounding air
temperature causing
thermal limit device to
shut down heater
This can happen when
running heater in
temperatures above 85
o
F.
Only run the heater in
cooler temperatures
Restricted air flow
Check heater inlet and
outlet. Remove any
obstructions
Output Rating
35,000 Btu/hr
Fuel
Propane Vapour
Gas Pressure
0.69 bar
Air Flow
169.8 m
3
/hr
Gas Consumption
0.74 kg/hr
Ignition Type
Manual, Piezo
Motor Voltage
230 Volt/50 Hertz
Power rating (Watts)
35
Fuse Rating (Amps)
3
Dimensions (D x W x H)
465 x 210 x 325 mm
Weight
5.4 Kg