Clarke Little Devil II Скачать руководство пользователя страница 12

12

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

TROUBLESHOOTING

WARNING: 

NEVER SERVI

C

E THE HEATER WHILE IT IS PLUGGED IN

CONNE

C

TED TO PROPANE SUPPLY

OPERATING OR HOT. SEVERE BURNS 

AND ELECTRICAL 

SHOCK CAN OCCUR.

OBSERVED 

FAULT

POSSIBLE CAUSE

REMEDY

Fan does not 
turn when 
heater 

is 

plugged in

No electrical power to the 
heater

Check voltage to 
electrical outlet. If voltage 
is good, check heater 
power cable for breaks

Structural damage

Return to your dealer for 
repair.

Defective motor

Return to your dealer for 
repair.

H

eater will not 

ignite 

User did not follow 
installation or operation 
instructions properly

Repeat installation and 
operation instructions. See 
Installation and Starting, 
page 8+9

No spark at ignitor. If no 
spark seen, the fault may 
be:

A) Loose or disconnected 
ignitor wire

B) Wrong spark gap

C) Piezo ignitor loose

D) Bad ignitor electrode

A) Check ignitor wire. 
Tighten or reattach loose 
ignitor wire. 

B) Set gap between 
ignitor electrode and 
target plate to 0.17" (0.43 
cm)

C) Tighten nut holding 
piezo ignitor to base of 
heater

D) Replace ignitor 
electrode.

If you see a spark at the 
ignitor have the heater 
serviced by a qualified 
service person.

 

Содержание Little Devil II

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0813 GAS HEATER Model No Little Devil II inc ss PART NO 6926020 6926025 SS...

Страница 2: ...these cases the local regulations should be consulted by the user GUARANTEE This product is guaranteed against faulty manufacture for a period of 12 months from the date of purchase Please keep your r...

Страница 3: ...t Dust is combustible 10 Keep the heater at least six feet from propane tank s Do not point the heater at propane tank s within 20 feet 11 Keep propane tank s below 100o F 37 8o C 12 Check the heater...

Страница 4: ...influence of alcohol or those at high altitude are more likely to be effected by Carbon Monoxide CO can build up in a confined space and failure to provide adequate ventilation can be fatal The early...

Страница 5: ...k The BROWN wire must be connected to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal which is marked E or or coloured green We strongly reco...

Страница 6: ...provides a stream of clean hot air THE IGNITION SYSTEM The piezo ignitor lights the burner THE AUTOMATIC CONTROL SYSTEM Should the flame extinguish for any reason the thermocouple will quickly cool ca...

Страница 7: ...VENT OF A GAS LEAK 1 Put out all smoking materials and other open flames 2 Do NOT operate electric switches or light matches 3 Close all supply valves on gas tank or cylinder 4 Do NOT use your phone U...

Страница 8: ...nk You must use the regulator supplied with heater 4 Open the propane supply valve on the propane tank s slowly NOTE If the supply valve is not opened slowly the check valve on the propane tank will a...

Страница 9: ...ank s slowly NOTE If not opened slowly the excess flow check valve on the propane tank will stop the gas flow If this happens close the propane supply valve and open again slowly WARNING PROVIDE AT LE...

Страница 10: ...ontrol valve button and wait 20 seconds for unburned fuel to exit the heater repeat steps 6 8 NOTE If the heater is unplugged or a power outage occurs while the heater is running the thermal limit dev...

Страница 11: ...nspect the heater before each use Check connections for leaks Apply mixture of liquid soap and water to connections Bubbles forming show a leak Correct all leaks at once 3 Inspect the hose regulator a...

Страница 12: ...r dealer for repair Defective motor Return to your dealer for repair Heater will not ignite User did not follow installation or operation instructions properly Repeat installation and operation instru...

Страница 13: ...hile running High surrounding air temperature causing thermal limit device to shut down heater This can happen when running heater in temperatures above 85o F Only run the heater in cooler temperature...

Страница 14: ...GFLDEV204 17 Hose regulator Assembly GFLDEV217 5 Fan GFLDEV205 18 Regulator Connector GFLDEV218 6 Thermal Switch Kit GFLDEV206 19 Air Tube GFLDEV219 7 Burner Tube Part 2 GFLDEV207 20 Piezo Ignitor GF...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 16: ......

Отзывы: