4

take additional precautions such as filtering of the mains supply. Consideration
should be given to  shielding the supply cable of permanently installed welding
equipment, in metallic conduit or equivalent. Shielding should be electrically
continuous throughout its length. The shielding should be connected to the welding
power source so that good electrical contact is maintained between the conduit
and the welding power source enclosure.

2.2  Maintenance of the welding equipment

The welding equipment should be routinely maintained according to the
manufacturers recommendations. All access and service doors and covers should
be closed and properly fastened when the welding equipment is in operation.
The welding equipment should not be modified in any way except for those
changes and adjustments covered in the manufacturers

instructions. In particular, the spark gaps of arc striking and stabilizing devices should
be adjusted and maintained according to the manufacturers recommendations.

2.3  Welding cables

The welding cables should be kept as short as possible and should be positioned
close together, running at or close to the floor level.

2.4  Equipotential bonding

Bonding of all metallic components in the welding installation and adjacent to it
should be considered. However, metallic components bonded to the work piece
will increase the risk that the operator could receive a shock by touching these
metallic components and the electrodes at the same time. The operator should
be insulated from all such bonded metallic components.

2.5  Earthing of the workpiece

Where the workpiece is not bonded to earth for electrical safety, nor connected
to earth because of its size and position, e.g. ships hull or building steelwork, a
connection bonding the workpiece to earth may reduce emissions in some, but
not all instances.

Care should be taken to prevent the earthing of the workpiece increasing the risk
of injury to users, or damage to other electrical equipment.

Where necessary, the connection of the workpiece to earth should be made by
a direct connection to the workpiece, but in some countries where direct
connection is not permitted, the bonding should be achieved by suitable
capacitance, selected according to national regulations.

2.6  Screening and shielding

Selective screening and shielding of other cables and equipment in the surrounding
area may alleviate problems of interference. Screening of the entire welding
installation may be considered for special applications.

Содержание King 35N

Страница 1: ...OPERATING MAINTENANCE INSTRUCTIONS 0706 PLASMA CUTTERS Model Nos King 35N King 55 PLASMA CUTTERS...

Страница 2: ...0V Fuse Rating T20A 230V T36A 230V Cutting Depth Steel Class C 4MM 10MM No Current Settings 1 2 Working Air Pressure 5 to 5 5 BAR 5 to 5 5 BAR Rated Air Delivery 100 L MIN 105 L MIN Protection IP21 IP...

Страница 3: ...efully in doing so you will ensure the safety of yourself and that of others around you and you can look forward to the Plasma Cutter giving you long and satisfactory service GUARANTEE This CLARKE pro...

Страница 4: ...rea Before installing welding equipment the user shall make an assessment of potential electromagnetic problems in the surrounding area Avoid using your inverter in the vicinity of a other supply cabl...

Страница 5: ...evel 2 4 Equipotential bonding Bonding of all metallic components in the welding installation and adjacent to it should be considered However metallic components bonded to the work piece will increase...

Страница 6: ...A hard hat should be worn when others work overhead Flammable hair preparations should not be used by persons intending to weld or cut B Toxic fume prevention Severe discomfort illness or death can re...

Страница 7: ...suitable fire extinguishing equipment during and for some time after welding or cutting if a appreciable combustibles including building construction are within 10m b appreciable combustibles are furt...

Страница 8: ...ye protection such as welding goggles used for oxy acetylene welding Should the cutting cable be burned replace it NEVER attempt to repair it yourself NEVER operate the machine with the covers removed...

Страница 9: ...high frequency spark The main arc will ignite as soon as the gas between the tip and the nozzle is ionised The power generator is essentially made up of a transformer a rectifying unit and an electron...

Страница 10: ...mponents which make up the unit such as the solenoid valve the power contactor etc MAIN CONTACTOR MAIN TRANSFORMER MAIN BRIDGE PLASMA TORCH CONTROL PCB AIR SOLENOID VALVE AIR INPUT AIR SUPPLY A compre...

Страница 11: ...10 KING 55 FRONT PANEL KING 35N FRONT PANEL Fig 3 Fig 2 GENERAL LAYOUT Warning Lamps Warning Lamps...

Страница 12: ...the mains lead are coloured in accordance with the followingcode Green Yellow Earth Blue Neutral Brown Live As the colours of the flexible lead of this appliance may not correspond with the coloured m...

Страница 13: ...nect the power supply cable to a source located as near as possible to the work area so that the unit can be switched off quickly in case of emergency Refe to Electrical Connections on page 12 Fuse ra...

Страница 14: ...ated on the front panel are off The green light should be ON indicating that the unit is supplied with power 7 Press the torch button and check whether the pressure indicated by the pressure gauge cor...

Страница 15: ...the workpiece To move the torch pull towards you rather than pushing away from you 11 To stop cutting remove the torch from the workpiece To extinguish the pilot arc release the trigger on the torch N...

Страница 16: ...ISCONNECTED No special tools are required to replace torch parts Simply unscrew the nozzle assembly and all components are easily replaced 1 The torch must be kept free of slag at all times to ensure...

Страница 17: ...drained out of the filter regulator 4 NOT CUTTING AS IT SHOULD You might be trying to cut metal that is too thick or you may be trying to cut too fast Move the cutting torch slower 5 ARC GOES OUT WHEN...

Отзывы: