PROBLEM

SOLUTION

PUMP WILL 
NOT START

1. Make sure that the power is switched on.

2. Check fuse (consult an electrician if in doubt).
3. If extension lead is fitted, check connections (consult an 

electrician if in doubt).

4. Internal thermal cut-out has not re-set. Leave for 5-10 

minutes and try again.

5. The impeller may be jammed. Disconnect from the mains 

supply and remove any objects that may be obstructing 
the impeller. 

6. Float switch may be jammed against side wall, or 

prevented from moving. 

7. Water level too low - float switch in OFF position - lift float 

to check switch.

8. If the pump still fails to start, consult your CLARKE dealer 

for advice. 

PUMP WILL 
START BUT NOT 
PUMP

1. Check that the inlet is not blocked.
2. Check that the discharge tube is not clogged or 

obstructed.

3. The head may be too great, i.e. you are trying to lift the 

water too great a distance for the pump to cope with. 
(“Specifications” on page 7).

4. Air bubble in the pump, produced during the plunge. 

Plunge the pump again, at an angle, and shake it whilst 
lowering to remove any air trapped in the system.

5. Impeller may be damaged - Consult your CLARKE dealer.

PUMP WILL 
NOT STOP

1. Float switch may be prevented from moving to the fully 

down position.

2. Float switch may be faulty. Consult your CLARKE dealer 

for advice.

PUMP STOPS 
RUNNING

1. Thermal overload has operated. Leave for 5-10 minutes 

and try again.

2. Pump has run dry, or float switch has cut in.

3. A foreign object has jammed the impeller.

Содержание HSEC1400A

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0218 ISS 1 ORIGINAL INSTRUCTIONS SUBMERSIBLE SEWAGE CUTTER PUMP MODEL NO HSEC650A 651A 1400A PART NO 7230290 7230295 7230243...

Страница 2: ...receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was inte...

Страница 3: ...r use and incorporate a cable suitable for use with Class I appliances 12 Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance PUMP SPECIFIC 1 Do not pump exp...

Страница 4: ...d to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal which is marked E or or coloured green HSEC651A must be connected to a protected 110V su...

Страница 5: ...tricted recommended minimum area of 50 x 50 cm ALWAYS raise and lower the pump using a rope attached to the lifting handle Take all necessary precautions as described on page 3 The pump inlet must be...

Страница 6: ...lead will change the depth of water at which the pump will turn on or off 5 When the pumping is finished disconnect the pump from the mains power supply OVERLOAD SWITCH These pumps are fitted with a...

Страница 7: ...GE When the pump is not being used for extended periods clean and dry it thoroughly and store it indoors If the pump is left in water it must be run at least once a week to prevent it from seizing up...

Страница 8: ...OFF position lift float to check switch 8 If the pump still fails to start consult your CLARKE dealer for advice PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check that the dis...

Страница 9: ...9 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM HSEC1400A...

Страница 10: ...Bearing Cover 24 Flange 6 Oil Seal Cover 25 Hose tail 7 Pump Housing 27 Handle 8 Cutter Impeller 50HZ 28 Float Switch 9 Strainer 29 Power Cable Set 10 Capacitor 33 Cable Clamp 12 Upper Bearing 34 Cabl...

Страница 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM HSEC650A 651A...

Страница 12: ...A07 Seal Plate 8 HG650A08 HG651A08 Impeller 9 HG650A09 HG651A09 Pump Casing 10 HG650A10 HG651A10 Strainer 11 HG650A11 HG651A11 Top Bearings 12 HG650A12 HG651A12 Lower Bearing 13 HG650A13 HG651A13 Doub...

Страница 13: ...13 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 16: ......

Отзывы: