Clarke HSEC1400A Скачать руководство пользователя страница 2

2

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

INTRODUCTION

Thank you for purchasing this CLARKE Submersible Sewage Cutter Pump.

The pump is fitted with a tungsten carbide cutter, and is especially suited for 
heavily polluted water containing waste solids, such as sewage, light slurry 
etc.

This pump is NOT designed for pumping heavy slurry, sludge, mud, salt water, 
or any water containing chemicals or other acidic contaminants. It is also not 
suitable for single chamber septic tanks.

GUARANTEE

This product is guaranteed against faulty manufacture for a period of 12 
months from the date of purchase. Please keep your receipt which will be 
required as proof of purchase. 

This guarantee is invalid if the product is found to have been abused or 
tampered with in any way, or not used for the purpose for which it was 
intended.

Faulty goods should be returned to their place of purchase, no product can 
be returned to us without prior permission. 

This guarantee does not effect your statutory rights.

ENVIRONMENTAL RECYCLING POLICY

Through purchase of this product, the customer is taking on the 
obligation to deal with the WEEE in accordance with the WEEE 
regulations in relation to the treatment, recycling & recovery and 
environmentally sound disposal of the WEEE.

In effect, this means that this product must not be disposed of with general 
household waste. It must be disposed of according to the laws governing 
Waste Electrical and Electronic Equipment (WEEE) at a recognised disposal 
facility.

Содержание HSEC1400A

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0218 ISS 1 ORIGINAL INSTRUCTIONS SUBMERSIBLE SEWAGE CUTTER PUMP MODEL NO HSEC650A 651A 1400A PART NO 7230290 7230295 7230243...

Страница 2: ...receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was inte...

Страница 3: ...r use and incorporate a cable suitable for use with Class I appliances 12 Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance PUMP SPECIFIC 1 Do not pump exp...

Страница 4: ...d to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal which is marked E or or coloured green HSEC651A must be connected to a protected 110V su...

Страница 5: ...tricted recommended minimum area of 50 x 50 cm ALWAYS raise and lower the pump using a rope attached to the lifting handle Take all necessary precautions as described on page 3 The pump inlet must be...

Страница 6: ...lead will change the depth of water at which the pump will turn on or off 5 When the pumping is finished disconnect the pump from the mains power supply OVERLOAD SWITCH These pumps are fitted with a...

Страница 7: ...GE When the pump is not being used for extended periods clean and dry it thoroughly and store it indoors If the pump is left in water it must be run at least once a week to prevent it from seizing up...

Страница 8: ...OFF position lift float to check switch 8 If the pump still fails to start consult your CLARKE dealer for advice PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check that the dis...

Страница 9: ...9 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM HSEC1400A...

Страница 10: ...Bearing Cover 24 Flange 6 Oil Seal Cover 25 Hose tail 7 Pump Housing 27 Handle 8 Cutter Impeller 50HZ 28 Float Switch 9 Strainer 29 Power Cable Set 10 Capacitor 33 Cable Clamp 12 Upper Bearing 34 Cabl...

Страница 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM HSEC650A 651A...

Страница 12: ...A07 Seal Plate 8 HG650A08 HG651A08 Impeller 9 HG650A09 HG651A09 Pump Casing 10 HG650A10 HG651A10 Strainer 11 HG650A11 HG651A11 Top Bearings 12 HG650A12 HG651A12 Lower Bearing 13 HG650A13 HG651A13 Doub...

Страница 13: ...13 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 16: ......

Отзывы: