SAFETY INSTRUCTIONS

GENERAL

1. Read all instructions before use 

and save these instructions for 
future use.

2. An approved residual current 

device (RCD) which has a 
tripping current of less then 30mA 

MUST

 be used for all operations.

3. The electrical supply must be the 

same as that on the rating plate.

4. Always make sure that your 

hands are dry when connecting 
or disconnecting from the mains 
supply.

5. Never pull the mains lead to 

disconnect the pump from the 
mains socket. 

6. The mains plug must be kept 

away from the water at all times.

7. Do not allow children or 

unauthorised people to touch the 
pump, cables or connections. 

8. Disconnect the pump from the 

mains supply when not in use.

9. If necessary have the pump 

repaired by a qualified person.

10. Keep the mains lead away from 

heat, oil and sharp edges.

11. If you have to use an extension 

lead with this product, it must be 
designed for outdoor use and 
incorporate a cable suitable for 
use with Class I appliances.

12. Disconnect the pump from the 

electrical supply and wear gloves 
during servicing or maintenance.

PUMP SPECIFIC

1. Do not pump explosive / 

flammable liquids or chemicals.

2. Never allow the pump to run dry 

or operate out of the water.

3. Submersible pumps should always 

be submerged and stored 
vertically.

4. Disconnect the pump from the 

mains supply before placing it 
into or removing it from the water.

5. Always check the plug, and all 

cables for damage before use. 

6. Do not use the pump if 

damaged. Refer to qualified 
service personnel for repair. 

7. Never carry or lower the pump by 

the power cable or float switch 
always use the handle or a rope 
tied securely to the handle.

8. Never insert your fingers into the 

pump whilst it is connected to the 
mains.

9. Never use the submersible pump 

in a swimming pool when there 
are people or animals in the pool.

10. Keep the pump clear of any 

sediment by standing it on a 
platform or brick or suspending it 
at a suitable depth.

11. Do not use the pump if the water 

is liable to freeze, as this can 
cause damage to the pump. 
Remove the pump from the 
water and store it in a frost free 
location.

Содержание HSEC1400A

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0218 ISS 1 ORIGINAL INSTRUCTIONS SUBMERSIBLE SEWAGE CUTTER PUMP MODEL NO HSEC650A 651A 1400A PART NO 7230290 7230295 7230243...

Страница 2: ...receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was inte...

Страница 3: ...r use and incorporate a cable suitable for use with Class I appliances 12 Disconnect the pump from the electrical supply and wear gloves during servicing or maintenance PUMP SPECIFIC 1 Do not pump exp...

Страница 4: ...d to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal which is marked E or or coloured green HSEC651A must be connected to a protected 110V su...

Страница 5: ...tricted recommended minimum area of 50 x 50 cm ALWAYS raise and lower the pump using a rope attached to the lifting handle Take all necessary precautions as described on page 3 The pump inlet must be...

Страница 6: ...lead will change the depth of water at which the pump will turn on or off 5 When the pumping is finished disconnect the pump from the mains power supply OVERLOAD SWITCH These pumps are fitted with a...

Страница 7: ...GE When the pump is not being used for extended periods clean and dry it thoroughly and store it indoors If the pump is left in water it must be run at least once a week to prevent it from seizing up...

Страница 8: ...OFF position lift float to check switch 8 If the pump still fails to start consult your CLARKE dealer for advice PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check that the dis...

Страница 9: ...9 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM HSEC1400A...

Страница 10: ...Bearing Cover 24 Flange 6 Oil Seal Cover 25 Hose tail 7 Pump Housing 27 Handle 8 Cutter Impeller 50HZ 28 Float Switch 9 Strainer 29 Power Cable Set 10 Capacitor 33 Cable Clamp 12 Upper Bearing 34 Cabl...

Страница 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com PARTS DIAGRAM HSEC650A 651A...

Страница 12: ...A07 Seal Plate 8 HG650A08 HG651A08 Impeller 9 HG650A09 HG651A09 Pump Casing 10 HG650A10 HG651A10 Strainer 11 HG650A11 HG651A11 Top Bearings 12 HG650A12 HG651A12 Lower Bearing 13 HG650A13 HG651A13 Doub...

Страница 13: ...13 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 14: ...14 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 16: ......

Отзывы: