OPERATION

STARTING

You should always fit a non-return valve to the suction line. (A foot valve and 
filter are available from your CLARKE dealer).

1. Close all taps on the discharge side of the pump.

2. After making sure that all precautions have been observed, switch on the 

pump at the mains supply.

• The green “Power On” LED will light up and the yellow “Pump On” 

LED will indicate that the pump has been started. 

• The pump will continue to operate for a few seconds enabling the 

system to fill and to reach the required pressure.

• If this amount of time is insufficient, the red LED “Failure” lights up. If 

this happens, open a tap and keep the “Restart” button pressed 
until the red LED goes off, then release the button and close the tap. 
The EPC800 will stop the pump at its maximum pressure.

RUNNING

The EPC800 is programmed to perform all the pump control operations 
automatically.

• If you open the outlet tap the EPC800 will detect a drop in pressure 

and start the pump.

When operational breakdowns occur, such as water loss, obstruction of the 
suction pipe, etc., the EPC800 recognizes the problem and the red “Failure” 
led lights up at the same time as the power to the pump is cut to prevent 
damage caused by dry running

1. Switch off the EPC800 at the mains.

2. Rectify the problem

3. Switch on the EPC800 at the mains and press the RESET button.

NOTE: 

The most common problems associated with water pump 

operation are leaks on the SUCTION side of the pump. Even a pin 
hole in the inlet hose is sufficient to seriously reduce suction.

CAUTION: ENSURE THE PUMP IS FULLY PRIMED BEFORE SWITCHING ON. 
SEE YOUR PUMP INSTRUCTION MANUAL FOR DETAILS.

Содержание EPC800

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0714 ELECTRONIC PUMP CONTROLLER MODEL NO EPC800 PART NO 7230698...

Страница 2: ...ovides automatic operation of your pump This in line device maintains water pressure from booster pumps by instantly sensing water usage and automatically starting or stopping the pump 2 It protects t...

Страница 3: ...fied in your pump manual CONNECTING THE PUMP TO THE EPC800 The EPC800 is fitted with two cables 1 One is fitted with a standard 13 amp plug When connected to the mains supply this cable carries the su...

Страница 4: ...is marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal which is marked E or or coloured green We strongly recommend that this machine is connected to the mains supply...

Страница 5: ...5 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com INSTALLATION...

Страница 6: ...l the red LED goes off then release the button and close the tap The EPC800 will stop the pump at its maximum pressure RUNNING The EPC800 is programmed to perform all the pump control operations autom...

Страница 7: ...PS MOTORS Connection of single phase 220V pumps up to 1 1 Kw Connection of single phase 220V pumps over 1 1 Kw through a remote control switch Connection of three phase 380V pumps through a remote con...

Страница 8: ...is blocked in the upper position The reset button is blocked The pump is unable to provide sufficient pressure Presence of leaks which are higher than the minimum flow 0 6 I min Intermittent pump wor...

Страница 9: ...ing recovery and environmentally sound disposal of the WEEE In effect this means that this product must not be disposed of with general household waste It must be disposed of according to the laws gov...

Страница 10: ...10 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 11: ...ational com ACCESSORIES Layflat Hoses Assorted Hose Clip Set CHT672 Available in 100 metre coils or per meter Available in 1 3 Diameter 26 piece assorted hose clip set in various sizes Including 8 x16...

Страница 12: ......

Отзывы: