Clarke EPC800 Скачать руководство пользователя страница 3

3

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

SAFETY PRECAUTIONS

1. DO NOT attempt to modify or alter the controller in any way.

2. Observe all electrical precautions. DO NOT allow the EPC800 to be 

submerged. Ensure it is protected from the elements at all times.

3. Read and comply with all precautions specified in your pump manual.

CONNECTING THE PUMP TO THE EPC800

The EPC800 is fitted with two cables,

1. One is fitted with a standard 13 amp plug.

• When connected to the mains supply, this cable carries the supply 

to both the EPC800 and the pump.

2. The other cable should be fitted with a trailing socket (not supplied). 

3. Insert the plug from the pump into the trailing socket.

IMPORTANT: If the EPC800 is to be connected to an outdoor electrical 
supply, make sure that both the plug and the socket are of a BS approved 
waterproof design and are protected from the elements.

Содержание EPC800

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0714 ELECTRONIC PUMP CONTROLLER MODEL NO EPC800 PART NO 7230698...

Страница 2: ...ovides automatic operation of your pump This in line device maintains water pressure from booster pumps by instantly sensing water usage and automatically starting or stopping the pump 2 It protects t...

Страница 3: ...fied in your pump manual CONNECTING THE PUMP TO THE EPC800 The EPC800 is fitted with two cables 1 One is fitted with a standard 13 amp plug When connected to the mains supply this cable carries the su...

Страница 4: ...is marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal which is marked E or or coloured green We strongly recommend that this machine is connected to the mains supply...

Страница 5: ...5 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com INSTALLATION...

Страница 6: ...l the red LED goes off then release the button and close the tap The EPC800 will stop the pump at its maximum pressure RUNNING The EPC800 is programmed to perform all the pump control operations autom...

Страница 7: ...PS MOTORS Connection of single phase 220V pumps up to 1 1 Kw Connection of single phase 220V pumps over 1 1 Kw through a remote control switch Connection of three phase 380V pumps through a remote con...

Страница 8: ...is blocked in the upper position The reset button is blocked The pump is unable to provide sufficient pressure Presence of leaks which are higher than the minimum flow 0 6 I min Intermittent pump wor...

Страница 9: ...ing recovery and environmentally sound disposal of the WEEE In effect this means that this product must not be disposed of with general household waste It must be disposed of according to the laws gov...

Страница 10: ...10 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...