APPLICATIONS

T

his computerised electronic unit can be used

to convert pumps into automatic booster sets.

The device provides 3 main functions:

It provides automatic operation of your
pump.

The unit will automatically switch the pump ON
when the water pressure drops to about 1.5 bar,
and switches the pump OFF when it reaches
its’ maximum  value. In practice, this means that
it switches the pump ON and OFF whenever
the tap or lance etc., is opened.

It protects the pump from running dry.

The unit has an integrated dry running  safety
circuit, which switches the pump OFF when
there is no water flow. This will result in the red
LED beiing displayed. (To restart the unit, the
reset button must be pressed.)

It automatically sets the cut-out
pressure. 
(This is normally the max.
pump pressure).

The cut-in pressure is preset during manufacture
to 1.5 bar - no manual adjustment should be
necessary.

IMPORTANT:

This device must not be installed more

than 14 metres below the delivery outlet.

SAFETY PRECAUTIONS

1.

DO NOT attempt to modify or alter the
pump in any way.

2.

Observe all electrical precautions. DO NOT
allow the unit to be submerged.
Ensure it is protected from the elements
at all times.

3.

Read and comply with all precautions
specified in your pump manual.

4.

If your pump is used for draining ponds or
swimming pools, ensure that before

operation all pond life is removed, and duriing
operation no person or animal is allowed in or
near the pool.

ELECTRICAL INSTALLATION

Connect the mains lead to a standard 230Volt
(50Hz) electrical supply through an approved
plug or a suitably fused isolator switch. We
recommend that these pumps be fitted with a
Residual Current Device (RCD).

WARNING:

THIS APPLIANCE MUST BE EARTHED

If the device is to be connected to an outdoor
electrical supply, make sure that both the plug
and the socket are of a BS approved waterproof
design.

In the event that the device is directly wired into
the electrical system, it must be carried out in
accordance with IEE regulations.

If used for draining swimming pools or ponds,
the device MUST be fitted with a Residual
Current Device (RCD), with a rated residual
operating current of no greater than 30mA.

IMPORTANT: The wires in the mains lead are
coloured in accordance with the following code:

Green & Yellow

-

Earth

 Blue

-

Neutral

Brown

-

Live

As the colours of the flexible cord of this
appliance may not correspond with the coloured
markings identifying terminals in your plug
proceed as follows:

Connect GREEN & YELLOW cord to plug
terminal marked with a letter “E” or  Earth symbol
“      “ or coloured GREEN or GREEN & YELLOW.

Connect BROWN cord to plug terminal marked
with a letter “L” or coloured RED

Connect BLUE cord to plug terminal marked
with a letter “N” or coloured BLACK

FUSE RATING

The fuse in the plug for this appliance must be
rated at 13 amps.

If this appliance is fitted with a plug which is
moulded onto the electric cable (i.e. non-
rewirable) please note: