Generator runs
but does not
support all
electrical
devices
Bad electrical device
connected to generator.
Try connecting a different device.
Generator is overloaded Perform these steps:
1. Turn off all electrical devices.
2. Unplug all electrical devices.
3. Turn off generator.
4. Wait several minutes.
5. Restart generator.
6.Try connecting fewer electrical loads
to the generator.
Short circuit in one of the
connected devices.
Try disconnecting any faulty electrical
loads.
There is AC
output but no
DC output
Burnt DC fuse
Replace with 8A fuse
Diode failure Replace diode