30
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
TROUBLESHOOTING
Problem Cause
Solution
Engine will not
start
No fuel in engine
Turn fuel valve to “open” position
(handle pointing down)
Air trapped in the fuel line Bleed fuel line
Generator is out of fuel
Add fuel
Not enough oil in crankcase Add or replace oil
Low-oil sensor failure
Add oil, disconnect low-oil sensor, start
engine and let run for several minutes,
then reconnect the sensor
Generator is not on level
surface
Move generator to a level surface to
prevent low oil shutdown from
triggering
Load was connected to the
generator
Disconnect all load devices from the
generator
Air cleaner is dirty
Replace air cleaner element
Battery is discharged
Charge the battery for 2 hours.
Battery is dead
Replace the battery
Engine needs maintenance
Get a professional engine tune-up
Engine stops
automatically
Generator is out of fuel
Add fuel
Fuel line is obstructed
Clean fuel tank and fuel filter. Bleed fuel
line
Air filter is dirty
Replace air filter element
Sudden increase to electrical
load.
Decrease the load
Black smoke
from exhaust
Generator is overloaded
Decrease load
Oil in cylinder
Check oil level, drain excessive oil from
crankcase
Not enough air or leaking air. Replace air cleaner element, check
and fix air leakage.
Fuel injection malfunction
Check injection pressure and spray
condition, change nozzle, or call
technical support.
White Smoke
from exhaust
There is water in diesel fuel Clean the fuel tank and fuel filter.
Change diesel fuel