 FAULTFINDING

Problem

Check

Solution

The pump fails to 
operate.

Check for power failure if 
pump is plugged in.

Check the switch is on and 
that the fuse is not blown.

Pump rotor jammed.

Motor fault.

Thermal cut-out has tripped.

Plug the pump into the 
socket.

Replace fuse or switch 
on.

Check for possible 
damage or obstruction 
of the rotating parts.

Return to Clarke Service 
Department for repair.

Wait for pump to cool 
down before re-starting.

Motor turns slowly 
when starting.

Low supply voltage.

Check electrical supply.

Lack of flow delivery. Low level in the storage 

tank.

Foot filter blocked.

Pump is positioned too high 
above the storage tank.

By-pass valve blocked.

Air entering the pump via 
the suction tubing.
Narrowing of the suction 
tubing.

Low pump speed.
Suction tubing is resting on 
the bottom of the tank.

Refill the tank.

Clean out the filter.

Position the pump lower 
in relation to the tank.

Return to Clarke Service 
Department for repair.

Check the tubing 
connections.
Tubing is damaged, 
blocked, or the wrong 
type of tubing being 
used.
Check the power supply.
Raise the tubing.

Leakage from the 
pump body.

Seal damaged.

Return to Clarke Service 
Department for repair.

Содержание DFT230

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC0816 230V DIESEL FUEL TRANSFER PUMP MODEL NO DFT230 PART NO 7160050...

Страница 2: ...yourself and that of others around you and you can look forward to your purchase giving you long and satisfactory service SPECIFICATIONS Please note that the details and specifications contained here...

Страница 3: ...NOT use this pump where there is a danger of fire 2 DO NOT use to pump ANY liquid other than diesel parafin and light fuel oil 3 ALWAYS ensure the ON OFF switch is in the OFF O position BEFORE connec...

Страница 4: ...ousehold waste It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment WEEE at a recognised disposal facility GUARANTEE This CLARKE product is guaranteed again...

Страница 5: ...rical hazard To ensure that the colours of the wires in the power cable correspond with the markings on the terminals of your plug proceed as follows The wire which is coloured Blue must be connected...

Страница 6: ...m CONTENTS ITEM DESCRIPTION 1 230 volt fuel transfer pump 2 Transparent Inlet suction Hose 1 BSP end fittings 3 Rubber Outlet delivery Hose 1 BSP end fittings 4 Dispensing Nozzle Assembly 5 1 BSP to 1...

Страница 7: ...of the pump with the inlet filter and the outlet hose to the side marked OUT on the pump body 7 Connect the dispensing nozzle to the outlet hose The hose and connections need to be completely air tig...

Страница 8: ...tarting Motor turns slowly when starting Low supply voltage Check electrical supply Lack of flow delivery Low level in the storage tank Foot filter blocked Pump is positioned too high above the storag...

Страница 9: ...e end of the inlet hose is kept clean Periodically remove the cover panel shown and clean the pump inlet filter as necessary Store the pump in dry conditions protected from the weather For any problem...

Страница 10: ...tional com DFT230 COMPONENT PARTS PART NO DESCRIPTION PART NO DESCRIPTION 1 Screw M5 x 10 10 Circlip 2 Front cover 11 By pass valve 3 O Ring 12 Filter 4 Rotor blade 13 Rubber gasket 5 Rotor 14 Filter...

Страница 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 12: ......

Отзывы: