Clarke DFT230 Скачать руководство пользователя страница 2

2

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

INTRODUCTION

Thank you for purchasing this CLARKE Pump. 

The DFTP230 pump is a self-priming rotary vane pump equipped with a by-pass 
valve and built-in filter on the inlet side. It is designed only for use with diesel 
fuels, parafin and light fuel oil. It must not be used with water, petroleum fuels 
or alcohol, nor if small solids are known to be in suspension.

Before attempting to use this product, please read this manual thoroughly and 
follow the instructions carefully. In doing so you will ensure the safety of yourself 
and that of others around you, and you can look forward to your purchase 
giving you long and satisfactory service.

SPECIFICATIONS

Please note that the details and specifications contained herein, are correct 
at the time of going to print. However, CLARKE International reserve the right 
to change specifications at any time without prior notice. Always consult the 
pump’s data plate.

Fluid Classification / Fluids to be used

Clean (parafin, light fuel oil, diesel)

Max. Head

6 m

Max. Flowrate (dependant upon 
temperature/type of oil)

56 l/min

Duty Cycle

Continuous

Max. Operating Temperature

10 - 70

o

 C

Max liquid temperature

40

o

 C

Weight (complete)

14 kg

Inlet Hose Length

2 m

Outlet Hose Length

2 m

Power cable length

2 m

Motor

230 Vac~50Hz

Input rated power

450 W

IP Rating

IP 54

Thermal overload protection fitted

Yes

Содержание DFT230

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC0816 230V DIESEL FUEL TRANSFER PUMP MODEL NO DFT230 PART NO 7160050...

Страница 2: ...yourself and that of others around you and you can look forward to your purchase giving you long and satisfactory service SPECIFICATIONS Please note that the details and specifications contained here...

Страница 3: ...NOT use this pump where there is a danger of fire 2 DO NOT use to pump ANY liquid other than diesel parafin and light fuel oil 3 ALWAYS ensure the ON OFF switch is in the OFF O position BEFORE connec...

Страница 4: ...ousehold waste It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment WEEE at a recognised disposal facility GUARANTEE This CLARKE product is guaranteed again...

Страница 5: ...rical hazard To ensure that the colours of the wires in the power cable correspond with the markings on the terminals of your plug proceed as follows The wire which is coloured Blue must be connected...

Страница 6: ...m CONTENTS ITEM DESCRIPTION 1 230 volt fuel transfer pump 2 Transparent Inlet suction Hose 1 BSP end fittings 3 Rubber Outlet delivery Hose 1 BSP end fittings 4 Dispensing Nozzle Assembly 5 1 BSP to 1...

Страница 7: ...of the pump with the inlet filter and the outlet hose to the side marked OUT on the pump body 7 Connect the dispensing nozzle to the outlet hose The hose and connections need to be completely air tig...

Страница 8: ...tarting Motor turns slowly when starting Low supply voltage Check electrical supply Lack of flow delivery Low level in the storage tank Foot filter blocked Pump is positioned too high above the storag...

Страница 9: ...e end of the inlet hose is kept clean Periodically remove the cover panel shown and clean the pump inlet filter as necessary Store the pump in dry conditions protected from the weather For any problem...

Страница 10: ...tional com DFT230 COMPONENT PARTS PART NO DESCRIPTION PART NO DESCRIPTION 1 Screw M5 x 10 10 Circlip 2 Front cover 11 By pass valve 3 O Ring 12 Filter 4 Rotor blade 13 Rubber gasket 5 Rotor 14 Filter...

Страница 11: ...11 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 12: ......

Отзывы: