FAULT CODE DISPLAY

The digital display can show the following fault codes.

HEATER SHUT DOWN & RE-STARTING

1. Set the power switch to the OFF position but do not unplug from the mains.

NOTE: 

When the heater is shut down, the fan will continue running for 5 

minutes to expel hot air and cool the casing. For this reason the 
heater should not be unplugged.

2. Only for extended shutdown should the heater be unplugged from the 

mains supply.

3. If re-starting, wait 10 seconds after shutting off the heater before re-starting.

4. Set the power switch to the ON position and follow the startup procedure 

above.

FAULT CODE

CAUSE

SOLUTION

FO:- Operation error

1. Heater is switched on
    before being plugged
    in.

1. Disconnect from power
    supply, switch off and
    then plug in again
    before switching on.

F1:- Photocell error

1. No fuel

2. Fuel is contaminated

3. Photocell is dirty or
     damaged.
4. Fuel Filter is dirty.
5. Ignition error

1. Switch off and refill the
     tank.
2. Switch off, empty and
   refill the fuel tank. Clean
    the filter with clean fuel.
3.Contact your dealer.

4. Clean filter.
5. Contact your dealer.

F2:- Temperature 
      control sensor error

1. Damaged cable
2. Sensor is damaged.

1. Contact your dealer.
2. Contact your dealer.

F3:-Thermostat error

1. Internal parts over
    heating.
2. Anti-tilting sensor 
    activated.

1. Turn the heater off and
    wait until it has cooled
    down.
2. Reposition heater on a
     level surface.

LO

1. External temperature

    below -9

o

C

1. Wait for normal 
   temperature conditions

CH

1. Air temperature over

    55

o

C.

1. Wait for normal 
    temperature conditions

Содержание Devil IRD20B

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS ORIGINAL INSTRUCTIONS GC0518 iSS 3 INFRARED DIESEL HEATER MODEL NO DEVIL IRD20B PART NO 6925500...

Страница 2: ...ich will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty...

Страница 3: ...umption 1 9 L per hour Fuel Tank capacity 10 5 litres Ignition type Direct spark Air displacement 400 m3 hr Continuous working time 6 hr before re fueling Over heating protection 120oC Max output 20 k...

Страница 4: ...eater or power cable to rain or wet conditions Any water entering the heater will increase the risk of electric shock 3 Never use the heater where petrol paint thinners or other highly flammable vapou...

Страница 5: ...s responsible for informing those present of the safety precautions and of the hazards involved 2 The heater is not to be used by children or people with reduced physical sensory or mental capabilitie...

Страница 6: ...e risk of electric shock 3 Keep the mains cable well away from machines and ensure an adequate electrical supply is close at hand so that the operation is not restricted by the length of the cable 4 A...

Страница 7: ...ard If the colours of the wires in the power cable of this product do not correspond with the markings on the terminals of your plug proceed as follows The wire which is coloured Blue must be connecte...

Страница 8: ...which are supplied loose SAFETY SYSTEMS The unit is fitted with a temperature limit sensor which is designed to turn the heater off if the temperature should rise to an unsafe level If the sensor is t...

Страница 9: ...ly if it should tip over beyond a pre determined angle PREPARATION UNPACKING 1 Remove heater from carton and remove all protective material used for shipment 2 Check the heater for any damage and noti...

Страница 10: ...h filter inside the filler neck for any trapped contamination and clean out if necessary When filling the heater make sure that the heater is level and do not overfill Use a funnel or can with a long...

Страница 11: ...ply 2 Set the power switch to the ON position The power on LED will illuminate and the digital temperature display will show the room temperature for up to 3 minutes Turn the temperature control knob...

Страница 12: ...CAUSE SOLUTION FO Operation error 1 Heater is switched on before being plugged in 1 Disconnect from power supply switch off and then plug in again before switching on F1 Photocell error 1 No fuel 2 F...

Страница 13: ...sk dealer to clean re gap replace spark plug 3 Clean replace fuel filter 4 Ask dealer to clean replace nozzle 5 Rinse out fuel tank with clean fresh fuel 6 Return to dealer 7 Return to dealer for repa...

Страница 14: ...e fuel has become contaminated with dirt or water empty the tank and refill with fresh fuel 4 The fuel filter should be removed and inspected for cleanliness before refilling the tank If foul remove a...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 16: ......

Отзывы: