![Clarke Devil 1250(ss) Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/clarke/devil-1250-ss/devil-1250-ss_operating-and-maintenance-manual_2614850009.webp)
9
STARTING PROCEDURE
!
WARNING
Before starting the heater, you MUST ensure that the minimum ventilation
requirements are observed to avoid the risk of carbon monoxide poisoning.
1.
Ensuring there is sufficient gas, and that it is correctly connected, open th
e
valve on the gas cylinder, and open the regulator valve which is adjacent
to the gas inlet pipe. (Not applicable on the Little Devil).
2.
Plug the heater in to a suitably earthed supply and observing all precautions
previously stated, push the fan switch to the ON (I) position, (A, Fig.3), and
ensure the fan operates.
3.
Fully depress the gas valve button (B, Fig. 3), which is adjacent to the gas
inlet pipe, and push the ignition button (C, Fig. 3), repeatedly until the burner
ignites. Keep the gas valve button (D, Fig. 3), depressed for a further 10
seconds approx, until the main flame is established.
Should the flame extinguish when the gas valve button is released, wait for
1 minute, before repeating the operation, this time, holding down the gas
valve button for a longer period.
NOTES:
The Little Devil and Devil 650/660 heaters have a fixed, regulated gas flow,
whereas all other models have a variable gas flow regulator, so that you can
regulate the heat output by adjusting the regulator pressure.
Turning the knob clockwise will increase the pressure, and therefore the output,
anticlockwise to decrease.
If ignition is difficult or irregular, ensure the fan is operating and that the air inlet
and outlet are completely clear. Also ensure that the electrode gap is correct,
and that the electrode is clean (see Maintenance).
IMPORTANT
:
Should the thermal overload protection feature operate, shut off the gas
supply and allow the unit to cool for at least 10 minutes with the fan running,
before attempting to relight the burner.
Should the other safety features (previously mentioned) operate, the heater
may be restarted once the cause of the problem has been found and rectified.
FIG 3
Содержание Devil 1250(ss)
Страница 14: ...14 PARTS DIAGRAM LITTLE DEVIL SS...
Страница 16: ...16 PARTS DIAGRAM DEVIL 650 660...
Страница 18: ...18 PARTS DIAGRAM DEVIL 850 860...
Страница 20: ...20 PARTS DIAGRAM DEVIL 1250 1260...
Страница 22: ...22 PARTS DIAGRAM DEVIL 1850...
Страница 24: ...24 PARTS DIAGRAM DEVIL 3000...
Страница 26: ...26 PARTS DIAGRAM DEVIL 3150...