10
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
MAINTENANCE
DAILY
1. Before use, drain water from the airline filter and compressor.
2. Pour a few drops of Clarke air-line oil, into the tool air inlet. This should be
carried out regardless of whether or not an in-line mini oiler is used. If an in-
line mini oiler is not used, this procedure should be repeated after every
two to three hours of use.
3. Keep the body of the tool clean and free from debris.
WEEKLY
• Check the air inlet screen filter
for blockage and clean if
necessary.
CLEANING
1. Grit or gum deposits in the tool
may reduce efficiency and cause
the tool to run erratically. This
condition can be corrected by
cleaning the air strainer and
flushing out the tool with gum
solvent or oil.
2. Failing this, the tool should be disassembled, thoroughly cleaned, dried
and reassembled.
3. The tool may be dismantled by removing the front cover using the hex key
supplied prior to replacing any worn or damaged parts. You may prefer to
take the tool to your Clarke dealer if internal maintenance is required.
4. While in a dismantled state, it may be desirable to grease the hammer
mechanism and applying a small amount of good quality bearing grease.
• This may be better left to your Clarke dealer.
• A hex key is provided for removing the end cover from the wrench.
WARNING: MAKE SURE THAT THE AIR TOOL IS DISCONNECTED FROM THE
AIR SUPPLY BEFORE STARTING ANY CLEANING, OR MAINTENANCE
PROCEDURES.
Содержание CAT131
Страница 16: ......