background image

3

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

SAFETY PRECAUTIONS

Before using your compressor it is in your own interest to read and pay attention 
to the following safety rules.

1.

Compressed air is dangerous. Do not point a jet of air at persons or animals, and do 
not discharge compressed air against the skin.

2.

DO NOT operate your compressor with the guard removed.

3.

Repairs must only be carried out by a qualified engineer. If problems occur, contact 
your Clarke dealer.

4.

Before carrying out any maintenance, make sure that the pressure is released from 
the air reservoir, and that the compressor is disconnected from the electrical supply.

5.

DO NOT leave pressure in the receiver overnight, or when transporting.

6.

DO NOT adjust, or tamper with the safety valves. The maximum pressure is factory 
set, and clearly marked on the compressor.

7.

DO NOT operate in wet or damp conditions. Keep the compressor dry at all times. 
Similarly, clean air will allow the compressor to work efficiently. Do not use in dusty or 
otherwise dirty locations. 

8.

Some of the metal parts can become quite hot during operation. Do not touch/
remove these until the compressor has cooled down.

9.

Always set the pressure regulator to the recommended setting for the tool.

10. When spraying flammable materials e.g. cellulose paint, ensure that there is 

sufficient airflow and keep clear of any source of ignition.

11. Before spraying any material always consult paint manufacturers instructions for 

safety and usage.

12. Protect yourself. Goggles will protect your eyes from flying particles. Face masks will 

protect you against paint spray and fumes.

13. Do not apply strain to electrical cables and make sure that air hoses are not kinked 

or wrapped around the compressor. 

14. When disconnecting air hoses or other equipment from your compressor, make sure 

that the air supply is turned off at the outlet and vent all pressurised air from within 
the reservoir and other equipment attached to it. 

15. Make sure that children and animals are kept well away from the compressor and 

any equipment attached to it.

16. Make sure that all individuals using the compressor have had the necessary training 

and have read and fully understand these operating instructions.

17. Make sure that any equipment or tool used in conjunction with your compressor, has 

a safe working pressure exceeding that of the compressor.

18. Be careful when transporting the compressor to prevent tipping over

19. Permanently installed systems must be installed by a competent engineer.

20. These compressors produce noise levels in excess of 70dB(A). Persons working near 

the compressor must be supplied with ear protection.

Содержание Boxer 14/100P

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS0413 100L BELT DRIVEN AIR COMPRESSOR MODEL NO BOXER 14 100P PART NO 2245205...

Страница 2: ...the date of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used...

Страница 3: ...tor to the recommended setting for the tool 10 When spraying flammable materials e g cellulose paint ensure that there is sufficient airflow and keep clear of any source of ignition 11 Before spraying...

Страница 4: ...damp environment Risk of accidental start up The compressor could start automatically in the event of a power cut and subsequent reset Do not move the compressor while it is connected to the power sou...

Страница 5: ...oured black The BROWN wire must be connected to the terminal which is marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal which is marked E or or coloured green We str...

Страница 6: ...the following Set the ON OFF switch to the OFF position pushed down Make sure that the compressor is on level ground Make sure that the supply voltage matches the voltage shown on the data label CHECK...

Страница 7: ...it from the power supply before you move it Always use the handle Do not lift by or put strain on valves or hoses ATTACHING AIR TOOLS 1 Attach the air hose to the outlet valve 2 Attach the air tool to...

Страница 8: ...e reservoir decreases CHECK THE SAFETY VALVE To make sure that the safety valve works correctly 1 Pull on the ring attached Air will be released when you pull on the ring and stop when released 2 If t...

Страница 9: ...rise the air hose 4 Disconnect the tool from the hose TURNING THE COMPRESSOR OFF 1 Follow steps 1 3 in Removing Tools From The Air Hose above 2 Disconnect the compressor from the power supply 3 Slowly...

Страница 10: ...fully drained RESET BUTTON This compressor has a thermal overload device If the motor gets too hot the thermal overload device cuts the power which prevents damage to the motor If the thermal overloa...

Страница 11: ...FILTER MONTHLY The air filter must be examined monthly more often in dusty conditions 1 Remove the securing bolt and pull the filter from the compressor 2 Unclip the front and rear of the filter and p...

Страница 12: ...of operation or every 6 months To empty the oil from the machine remove the oil drain plug from the crankcase CHECK THE NON RETURN VALVE EVERY 6 MONTHS If the reservoir pressure decreases for no appa...

Страница 13: ...w drive belt over the small pulley 4 Position part of the drive belt over the large pulley as shown 5 Rotate the large pulley by hand in a clockwise direction whilst guiding the belt on to it Take car...

Страница 14: ...0 Bar Voltage 230 VAC 50 60Hz Air Displacement 14 CFM Receiver Capacity 100 L Fuse Rating 13 A Dimensions L x W x H 1070 x 475 x 780 mm Guaranteed Sound Power Level 94 dB A Weight 67 kg Please note th...

Страница 15: ...mpressor does not reach the set pressure and overheats easily Compressor head gasket blown or valve broken 1 Return the machine to your nearest service agent Compressor does not start The reservoir ha...

Страница 16: ...16 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com EXPLODED DIAGRAM...

Страница 17: ...9 2X36X4 FN4105234 52 COLD START VALVE R1 4X2 2BAR FN4101047 141 SHROUD MK102 MK103 FN4105261 909 KIT GASKETS MK103 213167002 FN4105850 912 KIT PISTON RING MK103 113 FN4105674 920 PISTON KIT MK103 FN4...

Страница 18: ...18 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 19: ...19 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 20: ......

Отзывы: