Clarke 7230294 Скачать руководство пользователя страница 8

8

Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]

POSITIONING AND HOSE CONNECTION

Remove all packaging and make sure that the unit contains no visible 
damage. Dispose of all packaging appropriately.

CONNECTING THE PUMP

1. Connect the hose to the outlet adaptor.

2. Always use the largest diameter hose possible as any restriction will reduce 

capacity and put unnecessary strain on the motor especially if a long run 
of discharge hose is being used.

•  The outlet adaptor fitting allows for connection of 32 mm (1¼”) hose 

which should be secured with a hose clamp.

• Suitable hoses are available from your local CLARKE dealer.

POSITIONING THE PUMP

1. It may be safer to raise and lower the pump into deep water using a rope 

attached to the lifting handle.

2. Place the pump in a vertical position resting on a firm, flat surface in the 

area that you want to drain. If there is sediment in the operating area, the 
pump should be placed vertically on house bricks, or similar but ensure 
they are not likely to collapse. Never

 

position the pump on sand, silt, mud 

or ground which is likely to collapse.

3. Route the hose as straight as possible. Excessive bending of the hose could 

obstruct the flow of water, reduce the pumping volume or clog the pump 
with mud, thus disabling the pumps function. If the hose is kinked at its base 
it will create air pockets in the pump, causing it to operate in a partially dry 
state. Take care to straighten any kinks or bends in the hose.

4. Do not operate the pump if the water is too shallow. This will be below the 

level of the outlet elbow with the impeller fully immersed.

5. Allowance must also be made for the overall width of the pump including 

the outlet elbow on one side.

• When the pump is being used in a permanent or semi-permanent 

installation, a non-return valve should be fitted in the delivery hose. 
Suitable hoses and valves are available from your CLARKE dealer.

• Take all necessary precautions as described on pages 5-6.

• The pump inlet must be fully submerged before being switched on.

Содержание 7230294

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS GC08 22 ORIGINAL INSTRUCTIONS HIGH HEAD DRAINING PUMP MODEL NO CHHDP830 PART NO 7230294 ...

Страница 2: ...he head for the pump The pump is provided with a thermal overload cut out so that in the event that the pump becomes overheated due to becoming blocked etc it will shut off automatically When the blockage has been cleared the thermal cutout will cool down and re set and the pump can be re started Before attempting to use this product it is essential that you read this manual thoroughly and careful...

Страница 3: ... 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com OVERVIEW FEATURES 1 Water inlet screen 2 Power cable with plug 3 Water outlet elbow 4 Hose adaptor 5 Lifting handle Pump Performance curve ...

Страница 4: ...charge towards electrical wiring or equipment 4 ALWAYS store the pump out of reach of children and do not allow persons unfamiliar with these instructions to operate it 5 NEVER direct the discharge flow towards another person 6 ALWAYS thoroughly familiarise yourself with this pump its operation and follow all instructions in this manual 7 ALWAYS ensure that the pump is properly positioned where ne...

Страница 5: ...from a swimming pool when there is a person or animal still in the pool 11 NEVER install the pump on sand silt or mud which is likely to shift or collapse 12 NEVER modify this pump in any way Use it only for the purpose for which it is designed SERVICING REPAIRS 1 ALWAYS have the pump serviced by your local CLARKE dealer using only identical replacement parts This will ensure the safety of the pum...

Страница 6: ...this means that this product must not be disposed of with general household waste It must be disposed of according to the laws governing Waste Electrical and Electronic Equipment WEEE at a recognised disposal facility This product contains valuable raw materials Metal products should be takento your local civic amenity site for recycling of metal products Recycle unwanted materials instead of disp...

Страница 7: ... the power cable do not agree with the markings on the plug proceed as follows The BLUE wire must be connected to the terminal marked N or coloured black The BROWN wire must be connected to the terminal marked L or coloured red The YELLOW AND GREEN wire must be connected to the terminal marked E or or coloured green AN APPROVED RESIDUAL CURRENT DEVICE RCD WHICH HAS A TRIPPING CURRENT OF LESS THAN ...

Страница 8: ...e operating area the pump should be placed vertically on house bricks or similar but ensure they are not likely to collapse Never position the pump on sand silt mud or ground which is likely to collapse 3 Route the hose as straight as possible Excessive bending of the hose could obstruct the flow of water reduce the pumping volume or clog the pump with mud thus disabling the pumps function If the ...

Страница 9: ...DRY 6 Disconnect the pump from the mains supply before placing it into or removing it from the water 7 NEVER insert your fingers into the pump whilst it is connected to the mains 8 DO NOT use the pump if the water is liable to freeze as this can cause damage to the pump Remove the pump from the water and store it in a frost free location OVERLOAD PROTECTION These pumps are fitted with automatic th...

Страница 10: ...ed for pumping swimming pool water or salt water likely to leave chemical residues it should be flushed through with clean water before storage 4 When the pump is not being used for extended periods clean and dry it thoroughly and store in indoors if the pump is left in water it should be run occasionally to prevent it from seizing up 5 If the pump shows signs of wear or damage contact your CLARKE...

Страница 11: ...connect from the mains supply and remove any objects that may be obstructing the impeller 6 If the pump still fails to start consult your CLARKE dealer PUMP WILL START BUT NOT PUMP 1 Check that the inlet is not blocked 2 Check that the discharge tube is not clogged or obstructed 3 The head may be too great i e you are trying to lift the water too great a distance for the pump to cope with 4 Air bu...

Страница 12: ...12 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com COMPONENT PARTS ...

Страница 13: ...5 Washer 5 Bearing bracket 26 Screw 6 Seal cover 27 Screw 7 Impeller 28 Power cable 8 Impeller 29 Cable plate 9 Upper pump housing 30 Screw 10 Bottom pump housing 31 Pin 11 Base 32 Bolt 12 Strainer 33 Short screw 13 Capacitor 34 Long screw 14 Bearing 35 Washer 15 Bearing 36 Cap nut 16 Mechanical seal 37 Screw 17 Shaft sleeve 38 Washer 18 Oil seal 39 Bolt 19 O ring 40 Washer 20 O ring 41 Washer 21 ...

Страница 14: ...ate of purchase Please keep your receipt which will be required as proof of purchase This guarantee is invalid if the product is found to have been abused or tampered with in any way or not used for the purpose for which it was intended Faulty goods should be returned to their place of purchase no product can be returned to us without prior permission This guarantee does not effect your statutory ...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY ...

Страница 16: ......

Отзывы: